Risk analysis of the Unity 1.5T MR‐Linac adapt‐to‐shape workflow

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background and Purpose The adapt‐to‐shape (ATS) workflow on the Unity MR‐Linac (Elekta AB, Stockholm, Sweden) allows for full replanning including recontouring and reoptimization5. Additional complexity to this workflow is added when the adaptation involves the use of MIM Maestro (MIM Software, Cleveland, OH) software in conjunction with ...
Jiayi Liang   +13 more
wiley   +1 more source

Log file‐based quality assurance method for respiratory gating system

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background As medical linear accelerator technology advances, enabling higher dose rate deliveries, hypofractionation regimens has increased. This necessitates respiratory gating systems that synchronize radiation delivery with tumor position, requiring simple rigorous quality assurance (QA) to ensure treatment accuracy and patient safety ...
Wonjoong Cheon   +7 more
wiley   +1 more source

Evaluating feature extraction reproducibility across image biomarker standardization initiative‐compliant radiomics platforms using a digital phantom

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The aim of this study was to thoroughly analyze the reproducibility of radiomics feature extraction across three Image Biomarker Standardization Initiative (IBSI)‐compliant platforms using a digital phantom for benchmarking. It uncovers high consistency among common features while also pointing out the necessity for standardization ...
Han‐Back Shin   +5 more
wiley   +1 more source

Developing reference plans for evaluating global clinical trials credentialing and PSQA systems

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To develop a practical framework for creating a diverse set of validated reference plans (varying in complexity) and implement a workflow to introduce beam modeling, calibration, and delivery errors into the reference cohort to test and compare various dosimetry audit methodologies.
Fre'Etta M. D. Brooks   +13 more
wiley   +1 more source

The edge visualization metric: Quantifying the improvement of lung SBRT target definition with 4D CBCT

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Four‐dimensional cone‐beam CT (4D CBCT) incorporates oversampling of 3D data to reconstruct multi‐phase CBCT data sets representing distinct phases of the breathing cycle based on a diaphragmatic correlate of respiratory motion. Motion artifacts and blurring can be reduced relative to three‐dimensional cone‐beam (3D CBCT), allowing ...
Colton Baley   +4 more
wiley   +1 more source