Results 141 to 150 of about 297,336 (298)
Risk analysis of the Unity 1.5T MR‐Linac adapt‐to‐shape workflow
Abstract Background and Purpose The adapt‐to‐shape (ATS) workflow on the Unity MR‐Linac (Elekta AB, Stockholm, Sweden) allows for full replanning including recontouring and reoptimization5. Additional complexity to this workflow is added when the adaptation involves the use of MIM Maestro (MIM Software, Cleveland, OH) software in conjunction with ...
Jiayi Liang+13 more
wiley +1 more source
A paired-associates learning task involving two sensory modalities [PDF]
Harold A. Ries
openalex +1 more source
Log file‐based quality assurance method for respiratory gating system
Abstract Background As medical linear accelerator technology advances, enabling higher dose rate deliveries, hypofractionation regimens has increased. This necessitates respiratory gating systems that synchronize radiation delivery with tumor position, requiring simple rigorous quality assurance (QA) to ensure treatment accuracy and patient safety ...
Wonjoong Cheon+7 more
wiley +1 more source
Abstract Background The aim of this study was to thoroughly analyze the reproducibility of radiomics feature extraction across three Image Biomarker Standardization Initiative (IBSI)‐compliant platforms using a digital phantom for benchmarking. It uncovers high consistency among common features while also pointing out the necessity for standardization ...
Han‐Back Shin+5 more
wiley +1 more source
Supramodal and cross-modal representations of working memory in higher-order cortex. [PDF]
Park D+5 more
europepmc +1 more source
Developing reference plans for evaluating global clinical trials credentialing and PSQA systems
Abstract Purpose To develop a practical framework for creating a diverse set of validated reference plans (varying in complexity) and implement a workflow to introduce beam modeling, calibration, and delivery errors into the reference cohort to test and compare various dosimetry audit methodologies.
Fre'Etta M. D. Brooks+13 more
wiley +1 more source
Multimodal fusion transformer network for multispectral pedestrian detection in low-light condition. [PDF]
Li G+7 more
europepmc +1 more source
Abstract Purpose Four‐dimensional cone‐beam CT (4D CBCT) incorporates oversampling of 3D data to reconstruct multi‐phase CBCT data sets representing distinct phases of the breathing cycle based on a diaphragmatic correlate of respiratory motion. Motion artifacts and blurring can be reduced relative to three‐dimensional cone‐beam (3D CBCT), allowing ...
Colton Baley+4 more
wiley +1 more source
Cross-modality matches between color and size differences [PDF]
Paschal N. Strong, Zita E. Tyer
openalex +1 more source