Results 231 to 240 of about 587,913 (313)
We propose a suture‐complementary approach that integrates optical skin clearing with a strain‐programmable luminescent adhesive patch. Hyaluronic acid promotes transdermal delivery of tartrazine to improve optical clearing and stabilizes its interaction with a photosensitizer. Optical clearing increases the penetration depth of visible light into skin,
Seong‐Jong Kim +6 more
wiley +1 more source
Integrating LiDAR Sensor Data into Microsimulation Model Calibration for Proactive Safety Analysis. [PDF]
Igene M +5 more
europepmc +1 more source
ABSTRACT Electronic waste has emerged as a major environmental challenge, driven by the massive consumption and a limited lifetime of modern electronic devices, stimulating the development of sustainable electronics. Here, an all‐biomaterial gelatin‐choline‐citric acid ([Ch][CA]) ionogel is developed as an active binder to realize self‐sintered ...
Lin Guo +10 more
wiley +1 more source
Advancing Glaucoma Diagnosis: Employing Confidence-Calibrated Label Smoothing Loss for Model Calibration. [PDF]
Vijayan M, Prasad DK, Srinivasan V.
europepmc +1 more source
Oxygen‐tunnel (OT) indium tin oxide (ITO) vertical channel transistors (VCTs) enable reliable, high‐density gain‐cell memory for monolithic 3D integration. A sandwiched SiN/SiO2/SiN OT stack selectively regulates oxygen transport, suppressing parasitic electrode oxidation while stabilizing channel oxygen vacancies, thereby suppressing carrier injection
Hyeonho Gu +17 more
wiley +1 more source
Fast model calibration for predicting the response of breast cancer to chemotherapy using proper orthogonal decomposition. [PDF]
Christenson C +7 more
europepmc +1 more source
A soft, dual‐channel hydrogel patch enables simultaneous detection of wound temperature and strain by integrating ion‐diffusion‐mediated thermoelectric and resistive sensing. The conformal design maintains stable performance during motion, capturing subtle inflammatory and mechanical changes for continuous wound monitoring.
Yu Fang +7 more
wiley +1 more source
IMAGE-DRIVEN BIOPHYSICAL TUMOR GROWTH MODEL CALIBRATION. [PDF]
Scheufele K +4 more
europepmc +1 more source
A compostable PGS soft surgical robot with interchangeable modules integrates transient Mo tactile and Si thermal sensors for dual feedback. The device preserves its function after clinical‐grade sterilization, demonstrates stable actuation and cardiac tissue grasping with real‐time in vivo pulsatile monitoring, and biodegrades post‐use with soil‐safe,
Minseong Chae +27 more
wiley +1 more source
Ferroelectric tunnel junction devices based on epitaxial undoped ferroelectric HfO2 films demonstrate stable switching endurance of over 106 switching cycles, low write voltages of ±3 V, 16 measured resistance states, and neuromorphic capability.
Markus Hellenbrand +13 more
wiley +1 more source

