Results 121 to 130 of about 1,638,135 (339)

Fermilab muon g-2 experiment

open access: yesEPJ Web of Conferences, 2018
The Fermilab muon g-2 experiment will measure the muon anomalous magnetic moment aμ to 140 ppb – a four-fold improvement over the earlier Brookhaven experiment.
Gorringe Tim
doaj   +1 more source

Evaluating feature extraction reproducibility across image biomarker standardization initiative‐compliant radiomics platforms using a digital phantom

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The aim of this study was to thoroughly analyze the reproducibility of radiomics feature extraction across three Image Biomarker Standardization Initiative (IBSI)‐compliant platforms using a digital phantom for benchmarking. It uncovers high consistency among common features while also pointing out the necessity for standardization ...
Han‐Back Shin   +5 more
wiley   +1 more source

Can nonstandard neutrino interactions explain the XENON1T spectral excess?

open access: yesPhysics Letters B, 2020
We perform a constrained spectral fit analysis of the excess observed in the electron recoil energy spectrum by XENON1T with neutrino magnetic moment, charge radius, neutrino millicharge and new light vector and scalar mediators. Within limits allowed by
Amir N. Khan
doaj  

The edge visualization metric: Quantifying the improvement of lung SBRT target definition with 4D CBCT

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Four‐dimensional cone‐beam CT (4D CBCT) incorporates oversampling of 3D data to reconstruct multi‐phase CBCT data sets representing distinct phases of the breathing cycle based on a diaphragmatic correlate of respiratory motion. Motion artifacts and blurring can be reduced relative to three‐dimensional cone‐beam (3D CBCT), allowing ...
Colton Baley   +4 more
wiley   +1 more source

Workshop summary: Kaons@CERN 2023

open access: yesEuropean Physical Journal C: Particles and Fields
Kaon physics is at a turning point – while the rare-kaon experiments NA62 and KOTO are in full swing, the end of their lifetime is approaching and the future experimental landscape needs to be defined.
G. Anzivino   +62 more
doaj   +1 more source

Search for electric dipole moments in storage rings

open access: yesEPJ Web of Conferences, 2016
The JEDI collaboration aims at making use of storage ring to provide the most precise measurement of the electric dipole moments of hadrons. The method makes exploits a longitudinal polarized beam. The existence an electric dipole moment would generate a
Lenisa Paolo
doaj   +1 more source

A no-go theorem for non-standard explanations of the $\tau\to K_S\pi\nu_\tau$ CP asymmetry

open access: yesSciPost Physics Proceedings, 2019
A new tensor interaction is the only possibility to explain the $2.8\sigma$ tension observed by the BaBar collaboration in the CP asymmetry in $\tau\to K_S\pi\nu_\tau$ with physics beyond the Standard Model (BSM) realized above the electroweak scale.
Vincenzo Cirigliano, Andreas Crivellin, Martin Hoferichter
doaj   +1 more source

Producing high quality cranial SRS plans with 4Pi planning technique in a commercial clinical solution

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To generate high‐quality stereotactic radiosurgery (SRS) plans for single cranial lesions using 4Pi planning technique and compare these to our clinical “status quo” plans. Methods Eighteen vestibular schwannoma (VS) patients previously planned with Varian Eclipse RapidArc and treated on a Varian TrueBeam using 6FFF MV photon beams ...
Ganesh Narayanasamy   +4 more
wiley   +1 more source

Enhanced analysis of gating latency in 0.35T MR‐linac through innovative time synchronization of a motion phantom and plastic scintillation detector

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam.
Mateb Al Khalifa   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy