Dose rate correction of a diode array for universal wedge field dosimetric verification

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To study the performance of MapCHECK 3 (MC3) in measuring universal wedge fields and propose a dose rate correction strategy to improve MC3 measurement accuracy. Materials and methods Universal wedge fields with different wedge angles and field sizes were measured at different depths using MC3.
Linyi Shen   +6 more
wiley   +1 more source

Spontaneous and evoked synaptic vesicle release arises from a single releasable pool

open access: yesCell Reports
Summary: The quantal content of an evoked postsynaptic response is typically determined by dividing it by the average spontaneous miniature response. However, this approach is challenged by the notion that different synaptic vesicle pools might drive ...
Junxiu Duan   +3 more
doaj  

Bone‐wise rigid registration of femur, tibia, and fibula for the tracking of temporal changes

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background Multiple myeloma (MM) induces temporal alterations in bone structure, such as osteolytic bone lesions, which are challenging to identify through manual image interpretation. The large variation in radiologists' assessments, even at expert centers, further complicates diagnosis.
Arttu Ruohola   +5 more
wiley   +1 more source

Exploring surface‐guided systems for intelligent breathing‐adapted four‐dimensional computed tomography: A comparison to infrared‐based reflective marker systems

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study evaluates the technical feasibility of adapting a surface monitoring system, designed for conventional four‐dimensional computed tomography (4DCT), to an intelligent, breathing‐adapted 4DCT and examines its potential to expand the currently limited range of supported surrogate systems.
Niklas Lackner   +4 more
wiley   +1 more source

Assessing the rigidity of thermoplastic masks for head immobilization effectiveness in stereotactic radiosurgery

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract This study compared three Brainlab thermoplastic masks—Cranial 4pi basic, stereotactic (Close Mask V2), and open‐face—to see how well they limited head movement during Stereotactic Radiosurgery (SRS). Using a head phantom, we tested rotational movements (pitch, yaw, and roll) and measured displacements with the ExacTrac system.
Iris Pasion Apale   +2 more
wiley   +1 more source