Evaluation of dosimetric and spatial accuracy of a virtual cone technique for radiosurgery using linac‐integrated CBCT‐based polymer gel dosimetry

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study evaluates the dosimetric and geometric precision of a virtual cone technique using CBCT‐based polymer gel dosimetry, enabling radiation delivery, and imaging readout within an identical spatial coordinate system. Methods We created a C# script for a virtual cone technique that generates a treatment plan with 10 gantry arcs ...
Tenzin Kunkyab   +6 more
wiley   +1 more source

Speeding up adiabatic ion transport in macroscopic multi-Penning-trap stacks for high-precision experiments. [PDF]

open access: yesCommun Phys
von Boehn M   +8 more
europepmc   +1 more source

Evaluation of the system accuracy of frameless stereotactic radiosurgery using a combination of cone beam CT, six degrees of freedom couch, and surface image‐guided systems

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to evaluate the accuracy of the frameless linear accelerator‐based stereotactic radiosurgery (FSRS) system incorporating cone‐beam CT (CBCT), six degrees of freedom (6‐DoF) couch, room laser, and surface image‐guided (SG) systems.
Hao‐Wen Cheng   +4 more
wiley   +1 more source

Shielding resources for four common radiopharmaceuticals utilized for imaging and therapy: Tc‐99m, F‐18, I‐131, and Lu‐177

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction The use of radioactive materials in the United States has been tightly regulated by the Nuclear Regulatory Commission and other entities for many decades. In 2015, however, the Joint Commission began to require hospital‐based nuclear medicine departments to conduct shielding designs and evaluations for radioactive material areas ...
Michael Oumano   +12 more
wiley   +1 more source

Non-Markovian quantum exceptional points. [PDF]

open access: yesNat Commun
Lin JD   +5 more
europepmc   +1 more source

Design and validation of a novel dosimetry phantom for motion management audits

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background We present a novel phantom design for conducting end‐to‐end dosimetry audits for respiratory motion management of two anatomical treatment sites. The design enables radiochromic film measurements of the dose administered to the target throughout the respiratory cycle (motion‐included) and the dose delivered to the time‐averaged ...
Alex Burton   +5 more
wiley   +1 more source

Levitation and controlled MHz rotation of a nanofabricated rod by a high-NA metalens. [PDF]

open access: yesMicrosyst Nanoeng
Pi H   +6 more
europepmc   +1 more source

A Python package for fast GPU‐based proton pencil beam dose calculation

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Open‐source GPU‐based Monte Carlo (MC) proton dose calculation algorithms provide high speed and unparalleled accuracy but can be complex to integrate with new applications and remain slower than GPU‐based pencil beam (PB) methods, which sacrifice some physical accuracy for sub‐second plan calculation.
Mahasweta Bhattacharya   +4 more
wiley   +1 more source

Risk analysis of the Unity 1.5T MR‐Linac adapt‐to‐shape workflow

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background and Purpose The adapt‐to‐shape (ATS) workflow on the Unity MR‐Linac (Elekta AB, Stockholm, Sweden) allows for full replanning including recontouring and reoptimization5. Additional complexity to this workflow is added when the adaptation involves the use of MIM Maestro (MIM Software, Cleveland, OH) software in conjunction with ...
Jiayi Liang   +13 more
wiley   +1 more source