Results 131 to 140 of about 3,087,004 (370)

The edge visualization metric: Quantifying the improvement of lung SBRT target definition with 4D CBCT

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Four‐dimensional cone‐beam CT (4D CBCT) incorporates oversampling of 3D data to reconstruct multi‐phase CBCT data sets representing distinct phases of the breathing cycle based on a diaphragmatic correlate of respiratory motion. Motion artifacts and blurring can be reduced relative to three‐dimensional cone‐beam (3D CBCT), allowing ...
Colton Baley   +4 more
wiley   +1 more source

Producing high quality cranial SRS plans with 4Pi planning technique in a commercial clinical solution

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose To generate high‐quality stereotactic radiosurgery (SRS) plans for single cranial lesions using 4Pi planning technique and compare these to our clinical “status quo” plans. Methods Eighteen vestibular schwannoma (VS) patients previously planned with Varian Eclipse RapidArc and treated on a Varian TrueBeam using 6FFF MV photon beams ...
Ganesh Narayanasamy   +4 more
wiley   +1 more source

On the Dynamics and Acoustics of Cloud Cavitation on an Oscillating Hydrofoil [PDF]

open access: yes, 1994
Observations have been made of the growth and collapse of surface and cloud cavitation on a finite aspect ratio hydrofoil oscillating in pitch. The cavitation was recorded using both still and high-speed motion picture photography, and the variations ...
Brennen, Christopher E., McKenney, E. A.
core  

Enhanced analysis of gating latency in 0.35T MR‐linac through innovative time synchronization of a motion phantom and plastic scintillation detector

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam.
Mateb Al Khalifa   +4 more
wiley   +1 more source

Long‐term stability analysis of beam shape in a robotic radiosurgery system

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aimed to investigate the long‐term stability of CyberKnife beam profile parameters and assess their compliance with existing quality assurance (QA) guidelines. We evaluated beam profiles in both standard and diagonal planes over 3.5 years post‐installation to detect potential issues and ensure consistent beam quality.
Ryoichi Hinoto   +4 more
wiley   +1 more source

Economic Impact of Motion Picture and Video Production in Georgia [PDF]

open access: yes, 2008
This fiscal impact details the economic impact including employment and tax revenue associated with the film and video production industry in ...

core  

Home - About - Disclaimer - Privacy