Results 91 to 100 of about 3,594,163 (173)

Thin-film metrology of tilted and curved surfaces by imaging Mueller-matrix ellipsometry

open access: yes, 2019
For the vast majority of ellipsometric measurements, the application of planar substrates is mandatory and requires a proper sample alignment prior to the measurement.
Daniel Fischer   +9 more
core   +1 more source

A portable imaging Mueller matrix polarimeter based on a spatio-Temporal modulation approach: Theory and implementation

open access: yes, 2015
Imaging polarimeters have been largely used for remote sensing tasks, and most imaging polarimeters are division of time or division of space Stokes polarimeters.
Rodríguez-Herrera, OG   +3 more
core   +1 more source

Optimal Mueller matrix estimation in the presence of additive Gaussian or Poisson shot noise

open access: yes, 2012
International audienceWe address the optimization of Mueller polarimeters in the presence of additive Gaussian noise and signal-dependent shot noise, which are two dominant types of noise in most imaging systems.
Goudail, François, Anna, Guillaume
core   +1 more source

Polarization-Based Digital Histology of Human Skin Biopsies Assisted by Deep Learning

open access: yesPhotonics
Mueller polarimetry has proven to be a powerful optical technique to complement medical doctors in their conventional histology analysis. In this work, various degenerative and malignant human skin lesions were evaluated ex vivo using imaging Mueller ...
Deyan Ivanov   +7 more
doaj   +1 more source

Field of view extension in Mueller matrix microscopy for whole-slide imaging of biological samples

open access: yesResults in Optics
Quantitative measures of the interaction of polarized light with tissue have been established as a powerful tool for biomedical diagnosis in recent years.
Roman Demczylo   +3 more
doaj   +1 more source

Differential Mueller matrix imaging of partially depolarizing optically anisotropic biological tissues. [PDF]

open access: yesLasers Med Sci, 2020
Trifonyuk L   +11 more
europepmc   +1 more source

Completing an experimental nondepolarizing Mueller matrix whose column or row is missing Completing an experimental nondepolarizing Mueller matrix whose column or row is missing

open access: yes, 2019
International audienceThe authors report on an algebraic procedure, allowing for the completion of an experimental nondepolarizing Mueller matrix with a column or a row missing to a full 16-element one.
Razvigor Ossikovski   +3 more
core   +1 more source

Insights into polycrystalline microstructure of blood films with 3D Mueller matrix imaging approach. [PDF]

open access: yesSci Rep
Ushenko AG   +11 more
europepmc   +1 more source

Author Correction: Insights into polycrystalline microstructure of blood films with 3D Mueller matrix imaging approach. [PDF]

open access: yesSci Rep
Ushenko AG   +11 more
europepmc   +1 more source