Results 141 to 150 of about 29,023 (298)

Graphene‐Interfaced Stretchable Sweat Patch for Multiplexed Electrochemical Monitoring of IL‐6, Glucose, and Calcium Ions

open access: yesAdvanced Materials Technologies, EarlyView.
Flexible sweat sensor patch integrating graphene‑interfaced gold microelectrodes functionalized with bio‑receptors and ion‑selective membrane, coupled with a capillary‑driven microfluidic layer and portable potentiostat electronics for multiplexed monitoring of inflammatory, metabolic, and electrolyte biomarkers in microliter sweat volumes.
Roomia Memon   +4 more
wiley   +1 more source

Effects of stretching exercises on muscle tension, fatigue, strength, and lactic acid accumulation: A pre-experimental study among fish transport workers [PDF]

open access: yes
Fish transport workers in Indonesia lift loads more than the specified limits, both in weight and frequency. This could cause lactic acid accumulation, fatigue and reduced physical performance. The aim of this study was to assess the effect of stretching
Widjasena , Baju   +6 more
core   +2 more sources

Flexible Pressure Sensor With Co‐Optimized Sensitivity and Linearity Based on Gradient Toroidal Microstructures

open access: yesAdvanced Materials Technologies, EarlyView.
A flexible piezoresistive pressure sensor with gradient toroidal CNT/PDMS microstructures is reported. The hierarchical geometry enables sequential electrode contact, achieving a sensitivity of 256.20 kPa−1 and linear response (R2 = 0.99) over 0–1000 kPa.
Rongmei Wang   +8 more
wiley   +1 more source

Solid Particle‐Liquid Metal Mixtures for Robust High‐Current Interconnects in Stretchable Electronics and Soft Robotics

open access: yesAdvanced Materials Technologies, EarlyView.
Metallic microparticles dispersed in liquid metal interconnects mitigate electromigration‐induced failure by reconfiguring internal current density distributions. These fillers facilitate the growth of a robust, protective gallium oxide shell at elevated temperatures, shifting the failure threshold toward a thermal limit.
Ethan J. Krings   +6 more
wiley   +1 more source

Upcycling Compact Discs Into Ultra‐Stable, Flexible, and Stretchable Nanoporous Gold Electrodes for Enhanced Biosensing Performance

open access: yesAdvanced Materials Technologies, EarlyView.
This article highlights the development of robust and high‐performance flexible and stretchable biosensors that maintain long‐term functionality and optimal electrical conductivity under mechanical deformation, utilizing sustainable and cost‐effective manufacturing principles.
Mousa H. Aldosari, Ahyeon Koh
wiley   +1 more source

Analysis of the most common modalities of stretching exercises on mechanical muscle output [PDF]

open access: yes, 2016
Glavni cilj ovog rada je prikazati najnovija saznanja o učincima najčešćih modaliteta vježbi istezanja na mehanički izlaz mišića (jakost i brzinu) te definirati primjenu i doziranje različitih modaliteta vježbi istezanja neposredno prije sportske ...
Milunović, Miran
core  

Soft Robotic Excretory Care Simulator for Nursing Education: Functional and Perceptual Biomimetics Approach

open access: yesAdvanced Robotics Research, EarlyView.
A soft robotic simulator is developed to replicate the digital removal of feces (DRF), a sensitive yet essential nursing procedure. Integrating soft actuators, sensors, and a realistic rectal model, the simulator balances functional fidelity with perceptual realism. Engineering evaluations and nurse feedback confirm its potential to enhance training in
Shoko Miyagawa   +10 more
wiley   +1 more source

A study to assess the effectiveness of intradialytic muscle stretching exercises on the level of pain during muscle cramps among patients undergoing hemodialysis in a selected hospital at Kerala [PDF]

open access: yes, 2018
INTRODUCTION: Chronic kidney disease, also called chronic kidney failure, describes the gradual loss of kidney function. The kidneys filter wastes and excess fluids from the blood, which are then excreted in the urine.
Tom Mathew,
core  

Elimination of Necking and Aspect Ratio Dependence in Uniaxial Actuators by Continuous Fiber Reinforcement

open access: yesAdvanced Robotics Research, EarlyView.
A novel carbon fiber reinforcement for dielectric elastomer actuators enhances actuation force while decoupling electromechanical performance from the actuator's aspect ratio. Unlike conventional fiber reinforcements, it enables a uniform planar stretch state along the entire actuator.
Markus Koenigsdorff   +8 more
wiley   +1 more source

A Proof‐of‐Concept Assessment of a Novel Wearable Eyelid Muscle Device: A Pre‐Clinical Animal Cadaver Study for Eyelid Closure Restoration

open access: yesAdvanced Robotics Research, EarlyView.
This article introduces a soft wearable eyelid sling device incorporating a hydraulic soft artificial muscle (SAM) for achieving complete closure of an eyelid. The SAM is driven by a cam mechanism that provides a displacement profile closely matched with those of a healthy eyelid.
Patrick Pruscino   +7 more
wiley   +1 more source

Home - About - Disclaimer - Privacy