Comparison between MyoRing and 355°KERATACx in the management of keratoconus
Background Intracorneal implants have been proposed over the years as a possible easier way for managing keratoconus, having a favorable influence on the course of the disease. KERATACx is a relatively new form of intracorneal ring segments that has been
Eman S.M Edrees +4 more
doaj +2 more sources
Femtosecond Laser Implantation of a 355-Degree Intrastromal Corneal Ring Segment in Keratoconus: A Three-Year Follow-Up. [PDF]
Purpose. To evaluate the outcomes of femtosecond laser‐assisted implantation of a 355‐degree intracorneal ring (ICR) (Keraring) in patients with keratoconus in the three‐year follow‐up. Setting. Future Femtolaser Center, Sohag, Egypt. Design. Prospective interventional case series. Patients and Methods.
Abdellah MM, Ammar HG.
europepmc +2 more sources
COMPARATIVE ANALYSIS OF LONG-TERM CLINICAL AND FUNCTIONAL RESULTS OF THE INTRA-STROMAL MyoRing IMPLANTATIONS ACCORDING TO OPTIMIZED AND STANDARD TECHNOLOGIES USING A FEMTOSECOND LASER IN KERATOCONUS PATIENTS [PDF]
Purpose. Comparative analysis of long-term clinical and functional results of the intra-stromal MyoRing implantation according to standard techniques and optimized technologies using a femtosecond laser (FSL) in patients with keratoconus (KC), stages II ...
N. P. Pashtayev +3 more
doaj +2 more sources
Intrastromal corneal ring segments for keratoconus: a comprehensive review of different types [PDF]
This comprehensive review analyzes different types of intrastromal corneal ring segments (ICRS) used in the treatment of keratoconus, focusing on visual outcomes, complication rates, and patient selection criteria for INTACS, KeraRing, Ferrara Ring ...
Yehya Tlaiss, John Warrak, Elias Warrak
doaj +2 more sources
Comparative analysis of the correction of irregular postkeratoplastic astigmatism with scleral lenses and intrastromal ring implantation [PDF]
Background. Many patients after penetrating keratoplasty (PK) experience induced postkeratoplastic astigmatism, which is often irregular and causes an increase in corneal aberrations that reduce visual acuity and quality. The aim of the study. To conduct
M. V. Sinitsyn, N. A. Pozdeyeva
doaj +2 more sources
TERMS AND IMPACT ON A REFRACTIVE EFFECT OF A CORRECTION OF THE MYORING POSITION IN PATIENTS WITH KERATOCONUS [PDF]
Purpose. To determine the time periods and impact on the refractive effect of a correction of the MyoRing position in patients with keratoconus. Material and methods.
N. P. Pashtayev +2 more
doaj +2 more sources
Clinical outcomes after complete intracorneal ring implantation and corneal collagen cross-linking in an intrastromal pocket in one session for keratoconus. [PDF]
Purpose. The aim of this work was to evaluate the results after combined surgery implantation of full rings and CXL in one session in a group of patients with keratoconus during a 12‐month follow‐up. Material and Methods. The study included 22 eyes of 20 keratoconic patients, mean age of 28.41 (from 18 to 50) years.
Studeny P, Krizova D, Stranak Z.
europepmc +2 more sources
Purpose The aim of this study was to compare the results as regards efficacy, safety, and patient satisfaction between two combined procedures. The first is combined femtosecond laser myoring implantation with cross-linking (CXL) and the second is ...
Mohammed Iqbal H Ahmed Saleem
doaj +2 more sources
Continuous intracorneal ring implantation for treatment of myopic astigmatism [PDF]
Suzan Amana Rattan Department of Surgery, Al-Kindy College of Medicine, University of Baghdad, Baghdad, Iraq Abstract: We report a case of myopic astigmatism, not eligible for laser vision correction and with an anterior chamber depth below that ...
Rattan SA
doaj +2 more sources
COMPARATIVE ANALYSIS OF CLINICAL AND FUNCTIONAL RESULTS OF THE INTRASTROMAL SEGMENTS AND MYORING IMPLANTATIONS IN KERATOCONUS USING THE FEMTOSECOND TECHNOLOGY [PDF]
Purpose. A comparative analysis of clinical and functional results of the intrastromal segments and MyoRing implantations in keratoconusof the stages II and III using the femtosecond technology.Material and methods.
N. P. Pashtayev +2 more
doaj +1 more source