Earth Fault Location Using Negative Sequence Currents [PDF]
In this paper, a new method for locating single-phase earth faults on non-effectively earthed medium voltage distribution networks is proposed. The method requires only current measurements and is based on the analysis of the negative sequence components
Amir Farughian +2 more
doaj +4 more sources
A Robust Vector Current Controller with Negative-Sequence Current Capability for Grid-Connected Inverters [PDF]
This paper presents a vector current controller (in the synchronous reference, or the dq, frame) with negative-sequence current injection capability for three-phase grid-connected converters.
Houshang Karimi +3 more
doaj +5 more sources
Broken Rotor Bar Fault Detection for Inverter-Fed Induction Motor with Negative-Sequence Current Analysis [PDF]
This study examines the effectiveness of negative-sequence current analysis in identifying broken rotor bars for inverter-fed induction motors under different load and speed conditions. To improve diagnostic reliability, inverter-induced harmonics in the
Sarvarbek Ruzimov +3 more
doaj +2 more sources
In case of an asymmetrical fault in PV accessed system, the inverter will simultaneously control the outputs of positive and negative sequence currents.
XU Xiaochun +3 more
doaj +1 more source
VSC control strategy for HVDC compensating negative sequence and decaying DC components
This paper proposes a voltage source converter (VSC) control strategy for the high voltage direct current (HVDC) transmission systems compensating the negative sequence and decaying DC (DDC) components. The mathematical model of the grid fault current is
Wu Yanwei +4 more
doaj +1 more source
This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square (RMS) phasor-domain, fundamental-frequency, three-phase, and dynamic simulation tools.
Victor A.F. Almeida +2 more
doaj +1 more source
Unbalanced and Reactive Currents Compensation in Three-Phase Four-Wire Sinusoidal Power Systems
In an unbalanced linear three-phase electrical system, there are inefficient powers that increase the apparent power supplied by the network, line losses, machine malfunctions, etc.
Rafael Montoya-Mira +4 more
doaj +1 more source
An inter-turn fault (ITF) is one of the most frequent induction motor faults; thus, many previous works have studied its model and diagnosis. However, previous works, simplifying the specific distorted flux distribution by the ITF, presented induction ...
Seong-Hwan Im, Bon-Gwan Gu
doaj +1 more source
Practical calculation of asymmetric short circuit current of DFIG connected to distribution network [PDF]
In view of the existing complex analytic calculations of DFIG short-circuit current are hardly applied in engineering projects, a practical calculation of asymmetric short-circuit current of DFIG is proposed.
Fu Pengwu +4 more
doaj +1 more source
When the single-phase reclosing of the high-voltage circuit, there will be tremendous negative sequence current generation. The connection of inverter-type new energy sources may increase the negative sequence current of the power system.
Zhenxing Li +4 more
doaj +1 more source