Broken Rotor Bar Fault Detection for Inverter-Fed Induction Motor with Negative-Sequence Current Analysis [PDF]

open access: yesSensors
This study examines the effectiveness of negative-sequence current analysis in identifying broken rotor bars for inverter-fed induction motors under different load and speed conditions. To improve diagnostic reliability, inverter-induced harmonics in the
Sarvarbek Ruzimov   +3 more
doaj   +2 more sources

Unbalanced Current Sharing Control in Islanded Low Voltage Microgrids

open access: yesEnergies, 2018
This paper reports a new control strategy to improve sharing of unbalanced currents in islanded LV microgrids. This technique provides fast and effective sharing of positive-, negative- and zero-sequence currents, and is the first example of zero ...
Foad Najafi   +2 more
doaj   +1 more source

Turn-to-Turn Fault Diagnosis on Three-Phase Power Transformer Using Hybrid Detection Algorithm

open access: yesApplied Sciences, 2021
A power transformer (PT) in power generation or transmission is critical to maintaining electrical continuity. Fault detection on a PT is needed, especially of incipient faults, which are often caused by a turn-to-turn fault (TTF) before it develops into
Chien-Hsun Liu   +2 more
doaj   +1 more source

MMC-SST input-level control strategy considering power quality optimization

open access: yes电力工程技术, 2022
The surge of negative sequence component of current affects the waveform quality of grid side current and endangers the normal operation of the system when the three-phase voltage of solid state transformer (SST) in the distribution network is unbalanced
ZHAO Wei   +3 more
doaj   +1 more source

Negative sequence current accumulation difference based wind farm collection line protection for MMC-HVDC system

open access: yesEnergy Reports, 2023
During the fault of the wind power collection line of the MMC-HVDC system, the amplitude of the fault current may be limited due to the control of the converter, which leads to the severe limitation of traditional protection.
Peng Sun   +5 more
doaj   +1 more source

A timely switch fault ride-through method for VSC-HVDC system

open access: yes电力工程技术, 2022
In order to achieve the fault through of voltage source converter-based high voltage direct current (VSC-HVDC)system during alternating current (AC) system asymmetric faults and keep stability of the impedance at steadystate, a timely switch fault ...
WANG Ke   +5 more
doaj   +1 more source

Coordinated Control of DFIG Converters to Comply with Reactive Current Requirements in Emerging Grid Codes

open access: yesJournal of Modern Power Systems and Clean Energy, 2022
The doubly-fed induction generator (DFIG) is considered to provide a low-reactance path in the negative-sequence system and naturally comply with requirements on the negative-sequence reactive current in emerging grid codes.
Yuanzhu Chang   +5 more
doaj   +1 more source

Analysis of unbalanced clustered voltage and control strategy of clustered voltage balancing for cascaded H-bridge STATCOM

open access: yesJournal of Modern Power Systems and Clean Energy, 2019
To explore the clustered voltage balancing mechanism of the cascaded H-bridge static synchronous compensator (STATCOM), this paper analyzes the causes of unbalanced clustered voltage. The negative-sequence current caused by the compensation of unbalanced
Yu Jin   +4 more
doaj   +1 more source

Identification and location method of asymmetric faults in coal mine power network

open access: yesGong-kuang zidonghua, 2018
Three asymmetrical faults of singe-phase grounding, singe-phase line breakage and ferroresonance in coal mine power network are easily misjudged, and existing methods hardly identify the three faults correctly.
WANG Qingliang, QIN Jie, LIU Xinru
doaj   +1 more source

A Negative-sequence Current Injection Method to Mitigate Voltage Imbalances in Microgrids

open access: yesEletrônica de Potência, 2011
This paper proposes a control strategy to reduce the voltage imbalances by injection of a proper negative-sequence current into the microgrid. This task can be done by each inverter connected to the microgrid in a shared way.
Gustavo M. S. Azevedo   +4 more
doaj   +1 more source