Results 11 to 20 of about 1,154,191 (288)

Stator winding short-circuit fault detection in a permanent magnet synchronous motor (PMSM) using negative sequence current in time domain

open access: yesIngeniería e Investigación, 2009
A negative sequence analysis in time domain was applied to fault detection of permanent magnet synchronous motors (PMSM). The fundamental components of the motor terminal currents were obtained using a Notch filter, based on which the negative se- quence
Jabid E. Quiroga
doaj   +1 more source

Analysis and Compensation of Negative Phase-sequence for Traction Transformer

open access: yesKongzhi Yu Xinxi Jishu, 2014
It analyzed the characteristics of negative phase-sequence current for traction transformers with different connection types under different loads. The three-phase current asymmetry degree of traction transformers is serious under both traction load and ...
SHI Minghui   +3 more
doaj   +2 more sources

Calculation Method and Characteristic Analysis for Fault Current of Permanent Magnet Direct-Drive Wind Power System considering Positive and Negative Sequence Decomposition

open access: yesInternational Transactions on Electrical Energy Systems
In view of the fact that the influence of positive and negative sequence decomposition, which is widely used in positive and negative sequence decoupling control in control system, on the fault current calculation process is not deeply considered in the ...
Botong Li   +4 more
doaj   +2 more sources

Characteristics and Control Strategy of Cascaded SVG with Star-configuration Considering Negative-sequence Compensation

open access: yesKongzhi Yu Xinxi Jishu, 2013
This paper illustrated var and negative sequence comprehensive compensation principles of cascaded static var generator(SVG) with star-configuration. The mathematical expression of zero-sequence voltage was deduced, and subsequently zero-sequence voltage
XIONG Qiaopo, LUO An, ZENG Zhizhen
doaj   +2 more sources

Suppression of Negative Sequence Current on HVDC Modular Multilevel Converters in Offshore Wind Power

open access: yesJournal of Marine Science and Engineering
The High Voltage Direct Current (HVDC) transmission technology employing modular multilevel converters (MMCs) can effectively enhance the transmission efficiency and stability of offshore wind farms, thereby aiding the promotion of large−scale ...
Xiaoning Xu   +3 more
doaj   +2 more sources

Fault characteristic analysis of photovoltaic inverter considering negative sequence control strategy

open access: yesZhejiang dianli, 2023
In case of an asymmetrical fault in PV accessed system, the inverter will simultaneously control the outputs of positive and negative sequence currents.
XU Xiaochun   +3 more
doaj   +1 more source

VSC control strategy for HVDC compensating negative sequence and decaying DC components

open access: yesEnergy Reports, 2023
This paper proposes a voltage source converter (VSC) control strategy for the high voltage direct current (HVDC) transmission systems compensating the negative sequence and decaying DC (DDC) components. The mathematical model of the grid fault current is
Wu Yanwei   +4 more
doaj   +1 more source

Phasor-domain Dynamic Model of Asymmetric Current Injection Controller for Converter-interfaced Generator

open access: yesJournal of Modern Power Systems and Clean Energy, 2021
This paper presents a controller model of asymmetric current injection for converter-interfaced generators suitable for root-mean-square (RMS) phasor-domain, fundamental-frequency, three-phase, and dynamic simulation tools.
Victor A.F. Almeida   +2 more
doaj   +1 more source

Unbalanced and Reactive Currents Compensation in Three-Phase Four-Wire Sinusoidal Power Systems

open access: yesApplied Sciences, 2020
In an unbalanced linear three-phase electrical system, there are inefficient powers that increase the apparent power supplied by the network, line losses, machine malfunctions, etc.
Rafael Montoya-Mira   +4 more
doaj   +1 more source

Study of Induction Motor Inter-Turn Fault Part I: Development of Fault Models with Distorted Flux Representation

open access: yesEnergies, 2022
An inter-turn fault (ITF) is one of the most frequent induction motor faults; thus, many previous works have studied its model and diagnosis. However, previous works, simplifying the specific distorted flux distribution by the ITF, presented induction ...
Seong-Hwan Im, Bon-Gwan Gu
doaj   +1 more source