Broken Rotor Bar Fault Detection for Inverter-Fed Induction Motor with Negative-Sequence Current Analysis [PDF]
This study examines the effectiveness of negative-sequence current analysis in identifying broken rotor bars for inverter-fed induction motors under different load and speed conditions. To improve diagnostic reliability, inverter-induced harmonics in the
Sarvarbek Ruzimov +3 more
doaj +2 more sources
Unbalanced Current Sharing Control in Islanded Low Voltage Microgrids
This paper reports a new control strategy to improve sharing of unbalanced currents in islanded LV microgrids. This technique provides fast and effective sharing of positive-, negative- and zero-sequence currents, and is the first example of zero ...
Foad Najafi +2 more
doaj +1 more source
Turn-to-Turn Fault Diagnosis on Three-Phase Power Transformer Using Hybrid Detection Algorithm
A power transformer (PT) in power generation or transmission is critical to maintaining electrical continuity. Fault detection on a PT is needed, especially of incipient faults, which are often caused by a turn-to-turn fault (TTF) before it develops into
Chien-Hsun Liu +2 more
doaj +1 more source
MMC-SST input-level control strategy considering power quality optimization
The surge of negative sequence component of current affects the waveform quality of grid side current and endangers the normal operation of the system when the three-phase voltage of solid state transformer (SST) in the distribution network is unbalanced
ZHAO Wei +3 more
doaj +1 more source
During the fault of the wind power collection line of the MMC-HVDC system, the amplitude of the fault current may be limited due to the control of the converter, which leads to the severe limitation of traditional protection.
Peng Sun +5 more
doaj +1 more source
A timely switch fault ride-through method for VSC-HVDC system
In order to achieve the fault through of voltage source converter-based high voltage direct current (VSC-HVDC)system during alternating current (AC) system asymmetric faults and keep stability of the impedance at steadystate, a timely switch fault ...
WANG Ke +5 more
doaj +1 more source
The doubly-fed induction generator (DFIG) is considered to provide a low-reactance path in the negative-sequence system and naturally comply with requirements on the negative-sequence reactive current in emerging grid codes.
Yuanzhu Chang +5 more
doaj +1 more source
To explore the clustered voltage balancing mechanism of the cascaded H-bridge static synchronous compensator (STATCOM), this paper analyzes the causes of unbalanced clustered voltage. The negative-sequence current caused by the compensation of unbalanced
Yu Jin +4 more
doaj +1 more source
Identification and location method of asymmetric faults in coal mine power network
Three asymmetrical faults of singe-phase grounding, singe-phase line breakage and ferroresonance in coal mine power network are easily misjudged, and existing methods hardly identify the three faults correctly.
WANG Qingliang, QIN Jie, LIU Xinru
doaj +1 more source
A Negative-sequence Current Injection Method to Mitigate Voltage Imbalances in Microgrids
This paper proposes a control strategy to reduce the voltage imbalances by injection of a proper negative-sequence current into the microgrid. This task can be done by each inverter connected to the microgrid in a shared way.
Gustavo M. S. Azevedo +4 more
doaj +1 more source