Results 1 to 10 of about 12,733,262 (289)
During the fault of the wind power collection line of the MMC-HVDC system, the amplitude of the fault current may be limited due to the control of the converter, which leads to the severe limitation of traditional protection.
Peng Sun +5 more
doaj +2 more sources
Weak-Grid Tolerant Positive- and Negative-Sequence Current Control of Voltage-Source Converters [PDF]
Peer ...
Kukkola, Jarno +4 more
openaire +4 more sources
Unbalanced Current Sharing Control in Islanded Low Voltage Microgrids
This paper reports a new control strategy to improve sharing of unbalanced currents in islanded LV microgrids. This technique provides fast and effective sharing of positive-, negative- and zero-sequence currents, and is the first example of zero ...
Foad Najafi +2 more
doaj +1 more source
The growing relevance of voltage source converters (VSCs), and the deep impact they have on the development and maintenance of the electrical grid, increase the necessity of further research on how to deal with nonideal grid conditions from the VSCs ...
Pablo Montero-Robina +3 more
doaj +1 more source
Summary This paper proposes an improved transient negative-sequence calculation formula for a large-capacity nuclear power generator system under unbalanced network conditions. Because of the disadvantages of traditional transient negative-sequence ratings, I2*2 t is concluded to be inadequate for rating the generator imbalance capability.
Bao-jun Ge +4 more
openaire +1 more source
Turn-to-Turn Fault Diagnosis on Three-Phase Power Transformer Using Hybrid Detection Algorithm
A power transformer (PT) in power generation or transmission is critical to maintaining electrical continuity. Fault detection on a PT is needed, especially of incipient faults, which are often caused by a turn-to-turn fault (TTF) before it develops into
Chien-Hsun Liu +2 more
doaj +1 more source
MMC-SST input-level control strategy considering power quality optimization
The surge of negative sequence component of current affects the waveform quality of grid side current and endangers the normal operation of the system when the three-phase voltage of solid state transformer (SST) in the distribution network is unbalanced
ZHAO Wei +3 more
doaj +1 more source
Research on Life Loss of Generator Retainer Caused by Negative Sequence Current [PDF]
Abstract With a large number of wind and solar power sources connected to the power grid, higher requirements are put forward for the power generation equipment to respond to the power grid imbalance. The safety research of generator rotor retaining ring under the impact of negative sequence current is of great significance.
Yong Wang +3 more
openaire +1 more source
Detection of Internal Faults in Transformers By Negative Sequence Current
Initially it is very difficult to find out internal fault in transformer. These internal fault are hazardous and causes overheating of transformer oil and winding, it consequences as insulation failure because of this uninterrupted power supply cannot be continued. It is more difficult to detect internal fault in small ratting transformer.
Satyam Prakash, Vivek Mishra
openaire +1 more source
A computationally efficient current controller for simultaneous injection of both positive and negative sequences [PDF]
This work was supported by the Research Promotion Foundation (RPF, Cyprus, Project KOINA/SOLAR-ERA.NET/1215/06), by the Ministry of National Infrastructure Energy and Water (Israel) and the SOLAR-ERA.NET (European Union's Seventh Framework Programme). © 2017 IEEE. Personal use of this material is permitted.
Ali, Zunaib +3 more
openaire +1 more source