Results 151 to 160 of about 2,383,589 (201)

Negative-Sequence Current Injection of Transmission Solar Farms

IEEE Transactions on Power Delivery, 2020
Integrating solar generation brings about unique challenges in power system protection. Previous studies have found inverter-based resources featuring distinct fault responses compared to conventional generators. The reduction in fault current magnitude and lack of negative and zero sequence currents can fundamentally impact the way that the power ...
Gefei Kou   +4 more
openaire   +1 more source

A review of negative sequence current

2010 63rd Annual Conference for Protective Relay Engineers, 2010
Sequence component analysis plays an essential role in analyzing power system faults and explaining some power system phenomena. It is very well known that negative sequence current could cause rotor damage, and that damage is highly detrimental to rotating machines such as motors and generators.
John Wang, Randy Hamilton
openaire   +1 more source

Determining negative sequence currents of turbine generator rotors

2009 International Conference on Electrical Machines and Systems, 2009
In parallel to their dynamic duty synchronous generators must be capable of bearing permanently an additional negative sequence current of up to 10% of the rated current according to the IEC 60034–1 standard. On turbine generators this does not only charge the damper winding but causes eddy currents and losses in the solid rotor iron in parallel.
T. Bach   +5 more
openaire   +1 more source

Research on Negative-Sequence Electric Current Examination Method

Advanced Materials Research, 2011
This paper based on traditional ip, iq examination's method , introduces one kind of non-phase-locked loop's ip, iq method. this method avoids the mains frequency displacement the influence, causes the examination to be more conveniently. With the MATLAB simulation of software, obtain the satisfactory results, thus proving the usefulness of this method.
Kai Wang, Wen Jin Dai
openaire   +1 more source

Negative-sequence currents for line-to-line faults

Electrical Engineering, 1953
THE RECENT REVISION of the American Standards Association Standard for Rotating Electrical Machinery, C50, short-circuit clause specifies requirements for synchronous generators during 3-phase, line-to-ground, and line-to-line short circuits. A generator operating at rated kilovolt-amperes and power factor, with fixed excitation at 5-per-cent ...
R. F. Lawrence, R. W. Ferguson
openaire   +1 more source

Negative sequence current reduction for generator/turbine protection

Conference Record of the 1993 IEEE Industry Applications Conference Twenty-Eighth IAS Annual Meeting, 2002
The authors present a feasible method for negative sequence current reduction at the generator terminal through a special function static VAr compensator (SVC). A specially designed fixed-capacitor thyristor-controlled reactor SVC is used. Computer simulation and laboratory test results show that it can effectively reduce negative sequence current at a
W.-J. Lee   +3 more
openaire   +1 more source

A digital distance relay using negative sequence current

IEEE Transactions on Power Delivery, 1990
The configuration and performance of a recently developed digital distance relay using negative sequence current for remote backup protection are described. Since relays for remote backup protection are designed for remote faults, the fault current that is input to the relay is small due to the influence of current distribution factors.
Y. Ohura   +5 more
openaire   +1 more source