Negative-Sequence Current Injection for Fast Islanding Detection of a Distributed Resource Unit

IEEE Transactions on Power Electronics, 2008
This paper presents an active islanding detection method for a distributed resource (DR) unit which is coupled to a utility grid through a three-phase voltage-sourced converter (VSC). The method is based on injecting a negative-sequence current through the VSC controller and detecting and quantifying the corresponding negative-sequence voltage at the ...
Amirnaser Yazdani   +2 more
exaly   +3 more sources

Negative Sequence Current Control in Wind Power Plants With VSC-HVDC Connection

IEEE Transactions on Sustainable Energy, 2012
Large offshore wind power plants may have multi-MW wind turbine generators (WTG) equipped with full-scale converters (FSC) and voltage source converter (VSC) based high voltaage direct-current (HVDC) transmission for gridconnection. The power electronic converters in theWTG-FSC and the VSC-HVDC allow fast current control in the offshore grid.
Sanjay Kumar Chaudhary   +2 more
exaly   +3 more sources

A review of negative sequence current

2010 63rd Annual Conference for Protective Relay Engineers, 2010
Sequence component analysis plays an essential role in analyzing power system faults and explaining some power system phenomena. It is very well known that negative sequence current could cause rotor damage, and that damage is highly detrimental to rotating machines such as motors and generators.
John Wang, Randy Hamilton
openaire   +1 more source

Negative-Sequence Current Injection of Transmission Solar Farms

IEEE Transactions on Power Delivery, 2020
Integrating solar generation brings about unique challenges in power system protection. Previous studies have found inverter-based resources featuring distinct fault responses compared to conventional generators. The reduction in fault current magnitude and lack of negative and zero sequence currents can fundamentally impact the way that the power ...
Gefei Kou   +4 more
openaire   +1 more source

Negative-sequence currents for line-to-line faults

Electrical Engineering, 1953
THE RECENT REVISION of the American Standards Association Standard for Rotating Electrical Machinery, C50, short-circuit clause specifies requirements for synchronous generators during 3-phase, line-to-ground, and line-to-line short circuits. A generator operating at rated kilovolt-amperes and power factor, with fixed excitation at 5-per-cent ...
R. F. Lawrence, R. W. Ferguson
openaire   +1 more source

Determining negative sequence currents of turbine generator rotors

2009 International Conference on Electrical Machines and Systems, 2009
In parallel to their dynamic duty synchronous generators must be capable of bearing permanently an additional negative sequence current of up to 10% of the rated current according to the IEC 60034–1 standard. On turbine generators this does not only charge the damper winding but causes eddy currents and losses in the solid rotor iron in parallel.
T. Bach   +5 more
openaire   +1 more source