Results 71 to 80 of about 7,027,692 (242)
Fault-Tolerant Control Strategy for Neutral-Point-Clamped Three-Level Inverter
A fault-tolerant control technique is discussed for the Neutral-Point-Clamped (NPC) three-level inverter, which ensures that the NPC inverter operates normally even under device failures. A two-level leg is added to the NPC inverter; when the device open
Yanxia Shen +3 more
doaj +1 more source
The use of a direct torque control (DTC) drive is a well-known control strategy that is applied frequently to induction motors. Although torque and stator flux ripples are major disadvantages of this approach, using a higher-level inverter helps to ...
Yashar Farajpour +3 more
doaj +1 more source
Space vector modulation method to balance the neutral voltage for a three level inverter
This paper investigates the capacitor voltage balance scheme for a neutral point clamped inverter. A symmetrical space vector modulation is used to analyze the imbalance in neutral point voltage.
Elamalayil Soman, Deepak, +7 more
core +1 more source
TGF‐β1 stimulation downregulates lysosomal channel TRPML1 in pulmonary fibroblasts. The TRPML1 agonist ML‐SA5 suppressed fibroblast‐to‐myofibroblast activation and collagen production. Mechanistically, ML‐SA5 inhibited mTOR phosphorylation, restored autophagic flux, and its effects were enhanced by rapamycin (mTOR inhibitor) and reversed by MHY1485 ...
Jiatong Yao +10 more
wiley +1 more source
Safety and Efficacy of GLP‐1 Receptor Agonists in Adults With Epilepsy, Obesity, and Type 2 Diabetes
ABSTRACT Objective Managing obesity in patients with epilepsy is complicated by the weight‐gaining properties of essential antiseizure medications (ASMs) such as valproate and pregabalin. We evaluated the safety and efficacy of initiating glucagon‐like peptide‐1 receptor agonists (GLP‐1 RAs) in this population.
Hyoshin Son +3 more
wiley +1 more source
Anticoagulation Treatment Response Among Phenotypic ESUS Clusters: Evidence From CASPR
ABSTRACT Objective To evaluate treatment effect heterogeneity across phenotypic clusters of patients with cryptogenic embolic stroke using causal inference methods. Methods From a retrospective, multicenter cohort of patients with cryptogenic embolic stroke, we estimated the treatment effect of anticoagulation versus antiplatelet therapy in patients ...
Elena Badillo Goicoechea +53 more
wiley +1 more source
Fault-Tolerant Methods for Three-Level T-Type Inverter to Balance Neutral-Point Voltage
This paper proposes new fault-tolerant (FT) space-vector modulation (SVM) techniques for three-level T-type inverter (3L-T2I) to balance neutral-point voltage (NPV) under faulty conditions.
Duc-Tri do +3 more
doaj +1 more source
A Three-level Space Vector PWM Strategy Based on Variable Virtual Middle Vector
T-type three-level topology has been widely applied in power converters for its high efficiency and low output harmonics, and the performance of this converter is determined by the effect of its capacitor neutral point voltage control.
LIN Zhenjun +5 more
doaj
With the increasing penetration of distributed generation, electric vehicles and single-phase loads in the low-voltage distribution network, flexible interconnected systems face more prominent three-phase unbalance and direct-current (DC)-side voltage ...
Yangxin Qiu +6 more
doaj +1 more source
This paper proposes a new modulation strategy that balances the neutral-point voltage for three-level neutral-clamped inverter systems. The proposed modulation replaces the P-type or N-type small switching states with other switching states that do not ...
Lee, Kyo-Beum +2 more
core +1 more source

