Comparison of Goldmann applanation, non-contact, dynamic contour and tonopen tonometry measurements in healthy and glaucomatous eyes, and effect of central corneal thickness on the measurement results [PDF]
Aim To compare the correlation of intraocular pressure (IOP) measurements obtained using Goldmann applanation tonometry (GAT), non-contact tonometry (NCT), dynamic contour tonometer (DCT) and tono-pen (TP) in glaucomatous and healthy eyes, and to ...
Aydın Yildiz, Tekin Yasar
doaj +1 more source
Systematic review of the agreement of tonometers with goldmann applanation tonometry [PDF]
This review was part of the Surveillance for Ocular Hypertension study funded by the UK National Institute for Health Research Health Technology Assessment Programme (Project No. 07/46/02). J.C.
Azuara-Blanco, Augusto; id_orcid +28 more
core +1 more source
Biomechanical analysis and modeling of contact interface as applied in tonometry and bio-inspired skin sensors [PDF]
The modeling of contact interface, in which two entities are brought to interact with each other, either through direct contact or non-direct contact, is crucial in the understanding of robotics and biomedical research where such interface will determine
Nishiyama, Jun
core +1 more source
Dynamic ultra high speed Scheimpflug imaging for assessing corneal biomechanical properties
OBJECTIVE: To describe a novel technique for clinical characterization of corneal biomechanics using non-invasive dynamic imaging. METHODS: Corneal deformation response during non contact tonometry (NCT) is monitored by ultra-high-speed (UHS) photography.
Renato Ambrósio Jr +7 more
doaj +1 more source
Comparison of intraocular pressure between the non-contact tonometry and Goldmann applanation tonometry readings.
Bo Ram Seol (7387829) +2 more
core +1 more source
2.6 Validation of the Measurement of Aortic Stiffness by the CARDIS Laser Doppler Vibrometer
Purpose: There is a need for new tools to screen large populations for cardiovascular disease risk. The CARDIS consortium (European Union H2020 funding) developed an easy-to-use, non-contact device for measuring carotid to femoral pulse wave velocity ...
Louise Marais +8 more
doaj +1 more source
Interpreting the structure–function relationship in high myopia‐associated glaucoma: A review
Abstract Visual field (VF) interpretation in high myopia‐associated glaucoma (HMG) is challenging due to frequent structure–function discordance and coexisting myopia‐related changes. These changes may reduce the reliability of conventional structure–function mapping and increase the risk of misclassifying non‐glaucomatous VF abnormalities as ...
Ruby S. Chan +6 more
wiley +1 more source
Background To compare the accuracy of non-contact tonometry, Pentacam, and corneal visualization Scheimpflug technology (Corvis ST) for the measurement of intraocular pressure (IOP) after small incision lenticule extraction (SMILE) or femtosecond laser ...
Zhiqing Yang +3 more
doaj +1 more source
Abstract Purpose To assess the correlation between optical coherence tomography (OCT) and ultrasound pachymetry (USP) as methods for analysing central corneal thickness (CCT) and to evaluate ophthalmic factors affecting CCT. Methods The eyes of 3070 subjects of the Northern Finland Birth Cohort (NFBC) were examined at the age of 45–49 years.
Tuomas Qvist +3 more
wiley +1 more source
Abstract Purpose Dexamethasone eye drops are being introduced off‐label to prevent progression of severe retinopathy of prematurity (ROP). We evaluated ophthalmologic outcomes in early childhood after postnatal topical dexamethasone exposure in pre‐term infants at a standardized follow‐up examination.
Mariya Petrishka‐Lozenska +3 more
wiley +1 more source