Results 61 to 70 of about 11,475,779 (155)

Sustained Tear Film Exposure After Parenteral Cefovecin Administration in Dogs: Pharmacokinetics and Relevance to Canine Bacterial Keratitis

open access: yesVeterinary Ophthalmology, Volume 29, Issue 5, September 2026.
ABSTRACT Objective To characterize the tear film pharmacokinetics of parenterally administered cefovecin (Convenia) and compare tear concentrations with the minimum inhibitory concentrations (MICs) of common ocular pathogens. Animals Studied Six healthy research‐bred Beagles.
Meredith R. McClure   +5 more
wiley   +1 more source

Correlation of the Intra Ocular Pressure Measured by Non Contact Tonometer with the Perkins Applanation Tonometer and Study of Non Contact Tonometer as a Screening Tool [PDF]

open access: yesAl Ameen Journal of Medical Sciences, 2017
Background: Intra ocular pressure (IOP) measurement is essential in ophthalmological assessment as raised IOP is an important risk factor for development as well as progression of glaucoma.
Vallabha K, Vijayamahantesh M. Bijapur
doaj  

Five-year incidence of primary open-angle glaucoma and rate of progression in health center-based Korean population: the Gangnam Eye Study. [PDF]

open access: yesPLoS ONE, 2014
OBJECTIVE:To investigate the 5-year incidence and progression rate of primary open-angle glaucoma (POAG) in a health-center-based Korean population. METHODS:The study population comprised 5,021 subjects who participated in standardized health screening ...
Young Kook Kim   +4 more
doaj   +1 more source

Clinical Characterization of Glaucoma in 63 Pet Rabbits (Oryctolagus cuniculus) in Japan

open access: yesVeterinary Ophthalmology, Volume 29, Issue 5, September 2026.
ABSTRACT Objective To characterize the signalment and clinical presentation of glaucoma in pet rabbits. Animal Studied Client‐owned pet rabbits (n = 222) referred to an exotic specialty animal hospital for ophthalmic examination between 2007 and 2023.
Kumiko Kato   +3 more
wiley   +1 more source

Longitudinal Evaluation of Chromatic Pupillometry and Retinal Thickness in Dogs With Sudden Acquired Retinal Degeneration Syndrome

open access: yesVeterinary Ophthalmology, Volume 29, Issue 5, September 2026.
ABSTRACT Objective To determine longitudinal changes in chromatic pupillary light reflexes (cPLR) and retinal layers in dogs with sudden acquired retinal degeneration syndrome (SARDS). Animals Studied Clinical evaluation: Fifteen SARDS‐affected and nine control dogs.
Soohyun Kim   +6 more
wiley   +1 more source

The effect of non-contact tonometry on corneal topography

open access: yes, 1978
A sensitive photokeratoscope was used to determine the effect on corneal topography of non-contact tonometry in six subjects.
Carney, Leo G., Bowman, Kenneth J.
core  

Outcomes of 39 Canine Eyes Treated With Combined Endoscopic Cyclophotocoagulation and Ahmed Valve Gonioimplantation for Glaucoma

open access: yesVeterinary Ophthalmology, Volume 29, Issue 5, September 2026.
ABSTRACT Purpose To evaluate the long‐term (> 1 year) outcomes of vision and intraocular pressure (IOP) control in dogs with glaucoma undergoing combined endoscopic cyclophotocoagulation (ECP) and Ahmed valve gonioimplantation (AVG). Methods Medical records between 2020 and 2025 were reviewed. Outcomes evaluated included IOP control (< 25 mmHg), vision
Sanskruti S. Potnis   +6 more
wiley   +1 more source

Compounded 0.03% Tacrolimus in Cross‐Linked Hyaluronate Improves Ocular Surface Health in Dogs With Evaporative Dry Eye Disease

open access: yesVeterinary Ophthalmology, Volume 29, Issue 5, September 2026.
ABSTRACT Objective To assess the clinical effects of a compounded 0.03% tacrolimus in 0.75% cross‐linked hyaluronic acid (XHA) on tear quantity, quality, and ocular surface health in dogs with evaporative dry eye disease (EDED). Procedures Sixteen client‐owned dogs diagnosed with EDED (normal aqueous production yet reduced stability) were enrolled in ...
Lionel Sebbag   +4 more
wiley   +1 more source

Improving Non-Contact Tonometry through Advanced Applanation Techniques and Measurement of Corneal Deformation [PDF]

open access: yes, 2020
Glaucoma, a disease characterized by increased intraocular pressure (IOP) in the eyes, is the leading cause of preventable blindness worldwide. Accurate measurement of IOP is essential to early diagnosis of glaucoma in order to begin treatment and ...
Wu, Hongyi   +9 more
core   +1 more source

Comparative study between the applanation tonometry (Perkins) and thenon-contact tonometry (Topcon CT-20) in glaucoma and normal eyes

open access: yes, 1998
A tonometria de aplanação necessita da instilação de colírios, oferece potencial risco de infecção e pode ser alterada por vícios de aferição. Entre estes estão a hipofluorescência e a hiperfluorescência do filme lacrimal, a espessura corneana e o ...
Gus, Patricia Ioschpe   +5 more
core   +1 more source

Home - About - Disclaimer - Privacy