Results 211 to 220 of about 16,726,829 (263)
Some of the next articles are maybe not open access.
Phase-locked loop effect on non-detection zone of unintentional islanding
2015 17th European Conference on Power Electronics and Applications (EPE'15 ECCE-Europe), 2015The number of small power distributed generators connected to the low voltage distribution networks has increased the possibility of unintentional islanding operations. In this paper, the influence of the Synchronous Reference Frame — Phase Locked Loop (SRF-PLL) for single-phase and three-phase inverter, combined with the wider frequency and voltage ...
Riccardo Sgarbossa +5 more
semanticscholar +2 more sources
2015 IEEE Symposium on Computer Applications & Industrial Electronics (ISCAIE), 2015
An effective islanding detection technique is extremely important in safeguard Distributed Generation (DG) from incur a great impact due to unintentional islanding. Among commonly employed techniques, passive detection is known as the simplest and cheapest detection technique, but suffers large Non-Detection Zone (NDZ). This paper present an evaluation
A. I. Isa, H. Mohamad, Z. Yasin
semanticscholar +2 more sources
An effective islanding detection technique is extremely important in safeguard Distributed Generation (DG) from incur a great impact due to unintentional islanding. Among commonly employed techniques, passive detection is known as the simplest and cheapest detection technique, but suffers large Non-Detection Zone (NDZ). This paper present an evaluation
A. I. Isa, H. Mohamad, Z. Yasin
semanticscholar +2 more sources
Instability criterion to eliminate the Non-Detection Zone of the Sandia Frequency Shift method
2009 IEEE/PES Power Systems Conference and Exposition, 2009Sandia Frequency Shift (SFS) islanding detection method is considered amongst the most efficient islanding detection methods that possesses small Non-Detection Zone (NDZ) for inverter based Distributed Generation (DG). The NDZ of the SFS depends to a great extent on its design parameters.
H. Zeineldin, S. Kennedy
semanticscholar +2 more sources
Three-dimensional Non-detection Zone for Assessing Anti-islanding Detection Schemes
Electric Power Components and Systems, 2010Abstract The non-detection zone is a concept used to evaluate anti-islanding detection methods. The non-detection zone is defined as the loading condition for which an islanding detection method would fail to operate in a timely manner, and it is represented in terms of the load parameters.
H. Zeineldin +3 more
semanticscholar +2 more sources
2011 International Conference on Advanced Power System Automation and Protection, 2011
Until now, there is a great development in photovoltaic grid-connected power system. In addition, there is an ongoing research on the problems existed in the system. Islanding of photovoltaic grid-connected power system have adverse impact on power quality and utility equipments, affecting the performance of the utility even worse, it may damage people'
Yu-Guo Fan, Chen Li
semanticscholar +2 more sources
Until now, there is a great development in photovoltaic grid-connected power system. In addition, there is an ongoing research on the problems existed in the system. Islanding of photovoltaic grid-connected power system have adverse impact on power quality and utility equipments, affecting the performance of the utility even worse, it may damage people'
Yu-Guo Fan, Chen Li
semanticscholar +2 more sources
2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition, 2009
Islanding detection and anti-islanding protection are the essential functions of the gird-connected inverter in DG systems. This paper focuses on the Non-Detection Zone (NDZ) with passive islanding detection method for the DG system with the current control scheme.
Xuan-Cai Zhu +4 more
semanticscholar +2 more sources
Islanding detection and anti-islanding protection are the essential functions of the gird-connected inverter in DG systems. This paper focuses on the Non-Detection Zone (NDZ) with passive islanding detection method for the DG system with the current control scheme.
Xuan-Cai Zhu +4 more
semanticscholar +2 more sources
2015 IEEE 2nd International Future Energy Electronics Conference (IFEEC), 2015
In this paper, the Non Detection Zones (NDZs) of frequency drift anti-islanding were compared according to the structure of positive feedback loop for closed-loop power controlled Distributed Generators (DGs). It was reported that the NDZ of frequency drift anti-islanding is enlarged with closed-loop based constant power controller.
Byeong-Heon Kim, S. Sul
semanticscholar +2 more sources
In this paper, the Non Detection Zones (NDZs) of frequency drift anti-islanding were compared according to the structure of positive feedback loop for closed-loop power controlled Distributed Generators (DGs). It was reported that the NDZ of frequency drift anti-islanding is enlarged with closed-loop based constant power controller.
Byeong-Heon Kim, S. Sul
semanticscholar +2 more sources
Modeling and design of phase shift anti-islanding method using non-detection zone
Solar Energy, 2007Abstract Islanding phenomenon of a grid-connected independent generator like a photovoltaic (PV) system occurs when a section of a utility system is disconnected from the main utility voltage source, but the independent generator continues to energize the utility lines in the isolated section. Since islanding causes a safety hazard to utility service
Byunggyu Yu +3 more
semanticscholar +2 more sources
Renewable and Sustainable Energy Reviews, 2015
Abstract Islanding is one of the most important concerns of the grid connected distributed resources due to personnel and equipment safety. Many approaches have been proposed for islanding detection, which can be categorized into passive and active schemes.
H. Samet, Farid Hashemi, T. Ghanbari
semanticscholar +2 more sources
Abstract Islanding is one of the most important concerns of the grid connected distributed resources due to personnel and equipment safety. Many approaches have been proposed for islanding detection, which can be categorized into passive and active schemes.
H. Samet, Farid Hashemi, T. Ghanbari
semanticscholar +2 more sources
2009 Pacific-Asia Conference on Circuits, Communications and Systems, 2009
Islanding detection and protection is an important concern for grid connected photovoltaic (PV) power generation system due to personnel and equipment safety. Over/Under Voltage Protection (OVP/UVP) and Over/Under Frequency Protection (OFP/UFP) are basical inverter resident passive islanding detection method (IDM) for detecting an islanding condition ...
Zeng-Qiang Mi, Fei Wang
semanticscholar +3 more sources
Islanding detection and protection is an important concern for grid connected photovoltaic (PV) power generation system due to personnel and equipment safety. Over/Under Voltage Protection (OVP/UVP) and Over/Under Frequency Protection (OFP/UFP) are basical inverter resident passive islanding detection method (IDM) for detecting an islanding condition ...
Zeng-Qiang Mi, Fei Wang
semanticscholar +3 more sources