Results 221 to 230 of about 16,726,829 (263)
Some of the next articles are maybe not open access.
IET Renewable Power Generation, 2020
This study proposes a fast and precise voltage feedback-based islanding detection method (IDM) for grid-connected photovoltaic systems (GCPVSs) based microgrid.
Reza Bakhshi-Jafarabadi, J. Sadeh
semanticscholar +1 more source
This study proposes a fast and precise voltage feedback-based islanding detection method (IDM) for grid-connected photovoltaic systems (GCPVSs) based microgrid.
Reza Bakhshi-Jafarabadi, J. Sadeh
semanticscholar +1 more source
Occurrence Probability and Prediction of Unintentional Islands Using Non Detection Zones
2019 IEEE Power & Energy Society General Meeting (PESGM), 2019As a result of the increasing share of distributed generation in electric supply, the probability of unintentional electrical islands is also increasing. Unintentional islands occur when sub-grids with balanced active and reactive power are separated. Stable unintentional islands are hard to detect and pose a risk for normal grid operation as well as ...
Sebastian Palm, Peter Schegner
openaire +1 more source
Active Anti-Islanding technique with reduced Non-Detection Zone for Centralized Inverters
2018 International Power Electronics Conference (IPEC-Niigata 2018 -ECCE Asia), 2018This paper presents an active anti-islanding scheme for grid-tied centralized inverters for large Photovoltaic (PV) power plants. The proposed technique involves appropriate reactive power injection into the grid which results in the positive/negative rate of change of frequency.
Prashant Jain +5 more
openaire +1 more source
A Generic Method for the Determination of Non-Detection Zones in DER-Dominated Distribution Grids
2018 IEEE Power & Energy Society General Meeting (PESGM), 2018Efficiently calculating non-detection zones (NDZ) becomes increasingly important when evaluating unintentional islanding risks of distribution grids that are highly integrated with distributed energy resources (DER). In this paper, a rigorous theoretical method, the DER-Driven Non-Detection Zone (D2NDZ), is presented to estimate NDZ for any given ...
Yan Li +7 more
openaire +1 more source
Advances in Materials, 2021
The prostate‐specific antigen (PSA) has been widely used for the early diagnosis of prostate cancer during routine check‐ups. However, the low sensitivity of regular PSA tests in the PSA gray zone often means that patients are required to undergo further
Bin-Shuai Wang +11 more
semanticscholar +1 more source
The prostate‐specific antigen (PSA) has been widely used for the early diagnosis of prostate cancer during routine check‐ups. However, the low sensitivity of regular PSA tests in the PSA gray zone often means that patients are required to undergo further
Bin-Shuai Wang +11 more
semanticscholar +1 more source
NDT & E international, 2021
Non-destructive testing (NDT) of welded aluminium (Al) joints for quality assessment is of great importance to the automotive industry, among others. Currently, no post-process NDT technique can differentiate between the fusion zone and substrate for ...
J. Galos +8 more
semanticscholar +1 more source
Non-destructive testing (NDT) of welded aluminium (Al) joints for quality assessment is of great importance to the automotive industry, among others. Currently, no post-process NDT technique can differentiate between the fusion zone and substrate for ...
J. Galos +8 more
semanticscholar +1 more source
CIRED 2012 Workshop: Integration of Renewables into the Distribution Grid, 2012
Loss of mains protection (LOM) is among the most challenging issues related to the integration of distributed generation (DG). This paper presents simulation studies on the effect of multiple DG units on LOM protection. The results reveal an operational risk related to the active LOM detection methods.
Mäkinen Anssi +3 more
openaire +1 more source
Loss of mains protection (LOM) is among the most challenging issues related to the integration of distributed generation (DG). This paper presents simulation studies on the effect of multiple DG units on LOM protection. The results reveal an operational risk related to the active LOM detection methods.
Mäkinen Anssi +3 more
openaire +1 more source
2020 International Conference on Smart Grids and Energy Systems (SGES), 2020
In distribution system studies, Distributed Generation (DG) has become an important entity due to the power demand. The DG provides advantages such as improving the voltage profile, power loss reduction, increased power reliability, stability, and quality. The major issue that needs consideration is the islanded operation of the system.
Sowmya Ramachandradurai, Narayanan. K
openaire +1 more source
In distribution system studies, Distributed Generation (DG) has become an important entity due to the power demand. The DG provides advantages such as improving the voltage profile, power loss reduction, increased power reliability, stability, and quality. The major issue that needs consideration is the islanded operation of the system.
Sowmya Ramachandradurai, Narayanan. K
openaire +1 more source
Applied Mechanics and Materials, 2013
The quick & exact anti-islanding is a mandatory feature for grid-connected distributed generation system. The conventional passivity detection method has the biggish blind section and lower reliability, especially when the grid-connected inverter export power and burthen power are balanceable; the islanding detection often is disabled. And that the
Ji Hong Zhang +2 more
openaire +1 more source
The quick & exact anti-islanding is a mandatory feature for grid-connected distributed generation system. The conventional passivity detection method has the biggish blind section and lower reliability, especially when the grid-connected inverter export power and burthen power are balanceable; the islanding detection often is disabled. And that the
Ji Hong Zhang +2 more
openaire +1 more source
IECON 2007 - 33rd Annual Conference of the IEEE Industrial Electronics Society, 2007
The islanding effect of utility-interactive photovoltaic (UIPV) system may cause hazards for the grid equipment, and even danger to grid personnel. Therefore, reliable islanding detection is one of the crucial factors to connect grid for UIPV system. Over the years, a number of research works have been concentrated on the techniques of non-detection ...
Hui Wang +4 more
openaire +1 more source
The islanding effect of utility-interactive photovoltaic (UIPV) system may cause hazards for the grid equipment, and even danger to grid personnel. Therefore, reliable islanding detection is one of the crucial factors to connect grid for UIPV system. Over the years, a number of research works have been concentrated on the techniques of non-detection ...
Hui Wang +4 more
openaire +1 more source