Results 61 to 70 of about 801,210 (251)
Abstract Purpose Results of a prospective, randomized controlled trial at our institute demonstrate an association between the dose to the left hippocampus and neurocognitive decline post‐radiotherapy for patients with glioblastoma. To minimize the dose to the left hippocampus, a left hippocampus sparing model was created using RapidPlan (RP) and multi‐
Shima Y. Tari+9 more
wiley +1 more source
Point distributions in compact metric spaces [PDF]
We consider finite point subsets (distributions) in compact metric spaces. Non-trivial bounds for sums of distances between points of distributions and for discrepancies of distributions in metric balls are given in the case of general rectifiable metric spaces.
arxiv
Random Metric Spaces and Universality [PDF]
WWe define the notion of a random metric space and prove that with probability one such a space is isometricto the Urysohn universal metric space. The main technique is the study of universal and random distance matrices; we relate the properties of metric (in particulary universal) space to the properties of distance matrices. We show the link between
arxiv +1 more source
Non-absolute integrable function spaces on metric measure spaces [PDF]
Kuelbs-Steadman spaces are introduced in this article on a separable metric space with finite diameter and finite positive Borel measure. Kuelbs-Steadman spaces of the Lipschitz type are also discussed. Various inclusion properties are also discussed. In the sequel, we introduce HK-Sobolev spaces on metric mesure space which coincides with HK-Sobolev ...
arxiv
Multi‐institutional study on image quality for a novel CBCT solution on O‐ring linac
Abstract Introduction This work presents a multi‐institutional study on image quality provided by a novel cone beam computed tomography (CBCT). The main goal is to investigate the consistency of imaging performance across multiple institutions.
Luis Agulles‐Pedrós+11 more
wiley +1 more source
Differentiable structures on metric measure spaces: A Primer [PDF]
This is an exposition of the theory of differentiable structures on metric measures spaces, in the sense of Cheeger and Keith.
arxiv
Fine properties of metric space-valued mappings of bounded variation in metric measure spaces [PDF]
Here we consider two notions of mappings of bounded variation (BV) from the metric measure space into the metric space; one based on relaxations of Newton-Sobolev functions, and the other based on a notion of AM-upper gradients. We show that when the target metric space is a Banach space, these two notions coincide with comparable energies, but for ...
arxiv
Abstract Purpose This study compares the dosimetric accuracy of deep‐learning‐based MR synthetic CT (sCT) in brain radiotherapy between the Analytical Anisotropic Algorithm (AAA) and AcurosXB (AXB). Additionally, it proposes a novel metric to predict the dosimetric accuracy of sCT for individual post‐surgical brain cases.
Jeffrey C. F. Lui+3 more
wiley +1 more source
A review of artificial intelligence in brachytherapy
Abstract Artificial intelligence (AI) has the potential to revolutionize brachytherapy's clinical workflow. This review comprehensively examines the application of AI, focusing on machine learning and deep learning, in various aspects of brachytherapy.
Jingchu Chen+4 more
wiley +1 more source
Abstract Purpose The study evaluates rapid linear accelerator (Linac) single isocenter stereotactic radiosurgery (SRS) with Hyperarc for large target numbers. We compared to Gamma Knife (GK), which suffers from long treatment times and investigated causes of differences. Methods Linac SRS and GK treatment plans for patients receiving 18 Gy to the gross
Abram Abdou+4 more
wiley +1 more source