Results 31 to 40 of about 5,324,636 (272)
The usefulness of CorvisST Tonometry and the Ocular Response Analyzer to assess the progression of glaucoma. [PDF]
AbstractCorneal Visualization Scheimpflug Technology (CST) and Ocular Response Analyzer (ORA) measurements were carried out in 105 eyes of 69 patients with primary open-angle glaucoma. All patients had axial length (AL), central corneal thickness (CCT), intraocular pressure (IOP) with Goldmann applanation tonometry (GAT) and eight visual fields (VF)s ...
Matsuura M +5 more
europepmc +4 more sources
New Approach to the Analysis of Raw Data from the Ocular Response Analyzer. [PDF]
<b><i>Purpose:</i></b> The aim of this research was to present a new approach for the potential characteristics of the anterior eye, based on numerical analysis of the raw data from multiple measurements on 1 eye captured with use of the Ocular Response Analyzer (ORA).
Jóźwik A, Kasprzak H, Kuczma M.
europepmc +4 more sources
Corneal Biomechanical Measures for Glaucoma: A Clinical Approach
Over the last two decades, there has been growing interest in assessing corneal biomechanics in different diseases, such as keratoconus, glaucoma, and corneal disorders.
Abdelrahman M. Elhusseiny +2 more
doaj +1 more source
Effect of intravitreal bevacizumab injection on corneal in vivo biomechanics: A pilot study
Purpose: To evaluate the effect of intravitreal bevacizumab (IVB) injection on corneal biomechanical parameters as measured by the ocular response analyzer (ORA) and Corneal Visualization Scheimpflug Technology (CorVis).
Nasser Shoeibi +3 more
doaj +1 more source
Corneal biomechanics in glaucoma – A review of the current concepts and practice
Intraocular pressure (IOP) is currently the only modifiable risk factor in glaucoma. Since all our efforts are directed towards maintaining a stable IOP to halt glaucoma progression, proper understanding about the science behind IOP measurement and ...
Prasanna Venkataraman +2 more
doaj +1 more source
Abstract Background Goldmann applanation tonometry (GAT) has been the gold standard for intraocular pressure(IOP) measurement ,since its appearance in clinical practice around 50 years ago.(1) In spite of being almost unchallenged, the last few years have become a sustained search for a new standard ...
Rim Raafat Fayez +3 more
openaire +1 more source
A Clinical Description of Ocular Response Analyzer Measurements
To examine the interrelationships among the Ocular Response Analyzer (ORA; Reichert Ophthalmic Instruments, Buffalo, NY), Goldmann applanation tonometer (GAT), and corneal geometry measurements in a young, healthy sample.Central corneal radius, ORA, GAT, and central corneal thickness (CCT) measurements were taken in 99 subjects (age, 21 ± 2 years) who ...
William, Lau, David, Pye
openaire +2 more sources
Accuracy of a multiport network analyzer [PDF]
The accuracy of a multiport vector network analyzer, which uses a new calibration concept, has been compared with a 2-port network analyzer that implements the classical TRL procedure.
F. SAMPIETRO +9 more
core +1 more source
To Evaluate Corneal Biomechanical Changes after Strabismus Surgery with Ocular Response Analyzer
INTRODUCTION[|]Corneal biomechanical changes were also suspected and investigated after some scleral procedures but not after strabismus surgery. In this study we aimed to evaluate corneal biomechanical changes following strabismus procedures.with ocular
Ebru Demet Aygıt +4 more
doaj +1 more source
Background This study analyzed regional corneal thickness remodeling, biomechanical properties, and visual outcomes after femtosecond laser-assisted in situ keratomileusis combined with intraoperative accelerated corneal collagen crosslinking (LASIK Xtra)
Junjie Piao +4 more
doaj +1 more source