Results 201 to 210 of about 1,248,173 (353)

Empirical Physics‐Based Normal Behavior Modeling of Drive Train Temperatures With High‐Resolution Wind Turbine Operating Data

open access: yesWind Energy, EarlyView.
ABSTRACT The installed wind energy capacity increases every year. However, operation and maintenance costs still make up a considerable portion of the levelized costs of electricity. This costs can be greatly reduced by the application of suitable early fault detection methods. The supervisory control and data acquisition system of wind turbines is one
Timo Lichtenstein   +2 more
wiley   +1 more source

Nesting ecology of an ice‐associated seabird, Kittlitz's murrelet, at the northern edge of its range

open access: yesWildlife Society Bulletin, EarlyView.
We studied the Kittlitz's murrelet, an ice‐associated seabird of conservation concern, at the northern edge of its range. Over a 2‐year period, we estimated nest density and success at 2 sites, captured and telemetered nesting murrelets, and tested the use of a thermal camera to improve nest detection.
Michelle L. Kissling   +9 more
wiley   +1 more source

Multiterminal High‐Voltage Direct Current Projects: A Comprehensive Assessment and Future Prospects

open access: yesHigh Voltage, EarlyView.
ABSTRACT Multiterminal high‐voltage direct current (MT‐HVDC) systems are an important part of modern power systems, addressing the need for bulk power delivery and efficient renewable energy integration. This paper provides a comprehensive overview of recent advances in MT‐HVDC technology, including launched projects and ongoing initiatives.
Mohammad Hossein Mousavi   +3 more
wiley   +1 more source

Investigation of the Impact of XLPE Cable Ageing on Impedance Mismatch Characteristics and Unbalanced Behaviour in Hybrid Operation Systems

open access: yesHigh Voltage, EarlyView.
ABSTRACT In the Hainan–Guangdong interconnection project, oil leakage in oil‐filled cables required replacing the faulty core with a single core from a three‐core cross‐linked polyethylene (XLPE) cable, leading to mixed operation of XLPE and oil‐filled cables.
Liang Zou   +4 more
wiley   +1 more source

Micro Partial Discharge Characteristics of SF6 Under DC Voltage

open access: yesHigh Voltage, EarlyView.
ABSTRACT In gas‐insulated high‐voltage direct current (HVDC) devices, micro partial discharges (PD) caused by micro‐protrusions or surface roughness on conductors or enclosures may not cause immediate insulation system failure due to their weak discharge intensity.
Geng Chen   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy