Results 31 to 40 of about 2,526 (162)

ONSD measurement.

open access: yes, 2015
The ONSD measurement was assessed 3 mm posterior to the orbit. The ONSDs of the patient with increased ICPs were significantly enlarged.
Ying Chen (9697)   +6 more
core   +1 more source

Optic nerve sheath diameter (ONSD) and age.

open access: yes, 2013
Optic nerve sheath diameter (ONSD) and age.
Md Amir Hossain (491944)   +11 more
core   +1 more source

Impact of optic nerve sheath diameter variations on respiratory mechanics in ventilated traumatic brain injury patients: A pilot prospective observational study

open access: yesIndian Journal of Anaesthesia
Background and Aims: In traumatic brain injury (TBI) patients, elevated intracranial pressure leading to brain–lung interactions is well described. This study aimed to find the association between the optic nerve sheath diameter (ONSD) variations and ...
Divya Rana   +4 more
doaj   +1 more source

Bedside ultrasonographic evaluation of optic nerve sheath diameter for monitoring of intracranial pressure in traumatic brain injury patients: a cross sectional study in level II trauma care center in India [PDF]

open access: yesAcute and Critical Care
Background Optic nerve sheath diameter (ONSD) is an emerging non-invasive, easily accessible, and possibly useful measurement for evaluating changes in intracranial pressure (ICP).
Sujit J. Kshirsagar   +7 more
doaj   +1 more source

Diagnostic accuracy of ultrasonographic optic nerve sheath diameter for detecting increased intracranial pressure in traumatic brain injury: An umbrella review on previous systematic reviews

open access: yesHong Kong Journal of Emergency Medicine, Volume 33, Issue 5, October 2026.
Abstract Background Traumatic brain injury (TBI) frequently results in increased intracranial pressure (ICP), which may cause irreversible damage or fatality if not addressed. Prompt and precise detection of ICP is essential, particularly in emergency situations.
Amirreza Peyrovinasab   +5 more
wiley   +1 more source

Transorbital sonographic evaluation of normal optic nerve sheath diameter in healthy volunteers in Bangladesh.

open access: yesPLoS ONE, 2013
IntroductionMeasurement of optic nerve sheath diameter (ONSD) by ultrasound is increasingly used as a marker to detect raised intracranial pressure (ICP).
Rapeephan R Maude   +11 more
doaj   +1 more source

Liver Transplantation Despite Active Intracranial Hemorrhage in Acetaminophen‐Induced Acute Liver Failure: A Case Report

open access: yesClinical Case Reports, Volume 14, Issue 9, September 2026.
ABSTRACT Acute liver failure with intracranial hemorrhage poses difficult transplant decisions. We report acetaminophen‐induced acute liver failure with cerebral edema and active multifocal hemorrhage successfully managed with emergent liver transplantation and staged neurosurgical intervention.
Daryna Shnitser   +3 more
wiley   +1 more source

Evaluation of bedside sonographic measurement of optic nerve sheath diameter for assessment of raised intracranial pressure in adult head trauma patients

open access: yesJournal of Emergencies, Trauma and Shock, 2020
Aim: The aim was to evaluate the use of bedside sonographic measurement of the optic nerve sheath diameter (ONSD) in the assessment of elevated intracranial pressure in patients with head injury coming to the emergency department (ED).
Alvin Mathews   +3 more
doaj   +1 more source

The association between intracranial pressure and optic nerve sheath diameter on patients with head trauma

open access: yesArquivos de Neuro-Psiquiatria, 2021
Background: Although intracranial pressure (ICP) monitoring is the gold standard method for measuring intracranial pressure after traumatic brain injury, optic nerve sheath diameter (ONSD) measurement with ultrasound (US) is also used in the evaluation ...
Kaan Çelik, Bekir Enes Demiryurek
doaj   +1 more source

Optic nerve sheath diameter (ONSD) and head circumference.

open access: yes, 2013
Optic nerve sheath diameter (ONSD) and head circumference.
Md Amir Hossain (491944)   +11 more
core   +1 more source

Home - About - Disclaimer - Privacy