Results 61 to 70 of about 391,271 (261)
Optimized Fault-Tolerant Control of Dual Three-Phase PMSM Under Open-Switch Faults
In this article, an optimized fault-tolerant control (FTC) method without current judgement is proposed for open-switch faults (OSFs) in dual three-phase permanent magnet synchronous motor (DTPMSM) drives.
Lei Chen +4 more
doaj +1 more source
Open-circuit fault diagnosis of three-level inverter based on Park transformatio
In view of problems that existing neutral point clamped (NPC) three-level inverter fault diagnosis method needs large amount of calculation and its accuracy is affected by noise and load, an open-circuit fault diagnosis method of three-level inverter ...
REN Xiaohong +3 more
doaj +1 more source
An On-line Diagnostic Method for Open-circuit Switch Faults in NPC Multilevel Converters [PDF]
On-line condition monitoring is of paramount importance for multilevel converters used in safety-critical applications. A novel on-line diagnostic method for detecting open-circuit switch faults in neutral-point-clamped (NPC) multilevel converters is ...
Demerdash, Nabeel, He, Jiangbiao
core +2 more sources
The Ile181Asn variant of human UDP‐xylose synthase (hUXS1), associated with a short‐stature genetic syndrome, has previously been reported as inactive. Our findings demonstrate that Ile181Asn‐hUXS1 retains catalytic activity similar to the wild‐type but exhibits reduced stability, a looser oligomeric state, and an increased tendency to precipitate ...
Tuo Li +2 more
wiley +1 more source
We reconstituted Synechocystis glycogen synthesis in vitro from purified enzymes and showed that two GlgA isoenzymes produce glycogen with different architectures: GlgA1 yields denser, highly branched glycogen, whereas GlgA2 synthesizes longer, less‐branched chains.
Kenric Lee +3 more
wiley +1 more source
This article presents an open-switch fault detection method for a hybrid active neutral-point clamped (HANPC) inverter based on deep learning technology. The HANPC inverter generates a three-level output voltage with four silicon switches and two silicon
Sang-Hun Kim +5 more
doaj +1 more source
Both torque ripple and current harmonics are enlarged due to single-phase open-circuit fault of five-phase permanent magnet synchronous motor (FPMSM). Based on chaotic-particle swarm, an adaptive optimization fault tolerant control algorithm is proposed ...
Chaobo Chen +7 more
doaj +1 more source
An Advanced Three-Level Active Neutral-Point-Clamped Converter With Improved Fault-Tolerant Capabilities [PDF]
A resilient fault-tolerant silicon carbide (SiC) three-level power converter topology is introduced based on the traditional active neutral-point-clamped converter.
He, Jiangbiao +2 more
core +1 more source
Structural biology of ferritin nanocages
Ferritin is a conserved iron‐storage protein that sequesters iron as a ferric mineral core within a nanocage, protecting cells from oxidative damage and maintaining iron homeostasis. This review discusses ferritin biology, structure, and function, and highlights recent cryo‐EM studies revealing mechanisms of ferritinophagy, cellular iron uptake, and ...
Eloise Mastrangelo, Flavio Di Pisa
wiley +1 more source
Superconducting fault current limiter application in a power-dense marine electrical system [PDF]
Power-dense, low-voltage marine electrical systems have the potential for extremely high fault currents. Superconducting fault current limiters (SFCLs) have been of interest for many years and offer an effective method for reducing fault currents.
Blair, Steven Macpherson +5 more
core +1 more source