Results 91 to 100 of about 727,698 (345)

Investigation of Iron‐Aluminide‐Like Phase Composition in Complex Concentrated Fe32Cu12Ni11Ti16Al29 Alloy

open access: yesAdvanced Engineering Materials, EarlyView.
This work reveals the phase composition and quantitative morphology analysis of precipitation‐hardened Fe32Cu12Ni11Ti16Al29 complex‐concentrated alloy. The precipitates are shown to have a high coherency. Morphology transition between sphere, cuboidal, and elongated morphology is observed. Finally, the overaging behavior is captured using microhardness.
Rostyslav Nizinkovskyi   +4 more
wiley   +1 more source

Macular ganglion cell complex measurement in bilateral retrobulbar optic neuropathy without a relative afferent pupillary defect

open access: yesInternational Medical Case Reports Journal, 2018
Masatoshi Haruta, Hiroyuki Ohshima, Ryoji Yamakawa Department of Ophthalmology, Kurume University School of Medicine, Kurume, Japan Purpose: This study aimed to demonstrate the clinical usefulness of measuring the macular ganglion cell complex (GCC) for ...
Haruta M, Ohshima H, Yamakawa R
doaj  

Quality assessment of optic nerve disk images

open access: yesMokslas: Lietuvos Ateitis, 2010
Analysis of optic nerve disk is done for different categories of images. Optic nerve disk images of the same eye and of different eyes of good and bad quality are investigated using spectral, histogram, edge parameters.
Viktorija Puzienė, Darius Jegelevičius
doaj   +1 more source

UBVR observation of V1357 Cyg = Cyg X-1. Search of the optical radiation of the accretion disk [PDF]

open access: yes
Data from 30 nights of V 1357 Cyg observations in July, August, and September of 1977 are presented. The contribution of the disk to the optic brightness of the system is computed with regard for the heating of its surface by ultraviolet radiation from V
Shevchenko, V. S.
core   +1 more source

On the Deformation Behavior of Metastable CrMnNi Steels Processed by Directed Energy Deposition in Different Temperature Regimes

open access: yesAdvanced Engineering Materials, EarlyView.
In the present study, metastable CrMnNi steels with varying chemical compositions and a concomitantly altered stacking fault energy are processed via directed energy deposition and afterwards tested via tensile tests at different temperatures. The present study shows the influence of the manufacturing process on the elemental deformation mechanisms for
Julia Richter   +8 more
wiley   +1 more source

Spectral domain optical coherence tomography imaging in optic disk pit associated with outer retinal dehiscence

open access: yesClinical Ophthalmology, 2014
Chee Wai Wong,1,2 Doric Wong,1,2 Ranjana Mathur1,2 1Singapore National Eye Centre, Singapore; 2Singapore Eye Research Institute, Singapore Abstract: A 37-year-old Bangladeshi male presented with an inferotemporal optic disk pit and serous macular ...
Wong CW, Wong D, Mathur R
doaj  

Ocular ultrasound findings in optic disk melanocytoma

open access: yesRevista Mexicana de Oftalmología, 2017
Purpose: To describe the echographic characteristics of optic disk melanocytoma using a high resolution 10–20 MHz ophthalmic ultrasound. Methods: We conducted a 10-year retrospective review finding 9 cases with optic disk melanocytoma.
Andrés Lisker-Cervantes   +7 more
doaj   +1 more source

Comparative Study of Experimental Methods for Measuring Thermal Properties of 100Cr6 Steel Powders

open access: yesAdvanced Engineering Materials, EarlyView.
This study investigates the thermal properties of 100Cr6 steel in both bulk and powder forms. Measuring the very low thermal conductivity typically exhibited by powders poses significant challenges. To address this, two novel measurement techniques—temperature gradient and finite laser pulse response—are introduced and evaluated by comparison with the ...
Junsheng Zhuo   +8 more
wiley   +1 more source

FEATURE EXTRACTION OF RETINAL IMAGE FOR DIAGNOSIS OF ABNORMAL EYES [PDF]

open access: yesICTACT Journal on Image and Video Processing, 2011
Currently, medical image processing draws intense interests of scien- tists and physicians to aid in clinical diagnosis. The retinal Fundus image is widely used in the diagnosis and treatment of various eye diseases such as Diabetic Retinopathy, glaucoma
S. Praveenkumar
doaj  

Key Trends and Insights in Smart Polymeric Skin Wearable Patches

open access: yesAdvanced Engineering Materials, EarlyView.
Intelligent polymers, which respond to various physical and biological stimuli, are explored for the development of skin wearable patches in biomedical applications. Smart polymers, also known as intelligent or stimuli‐responsive polymers, play a crucial role in the development of advanced wearable patches due to their versatility and softness.
Sergio J. Peñas‐Núñez   +2 more
wiley   +1 more source

Home - About - Disclaimer - Privacy