Results 41 to 50 of about 2,596,546 (331)
Ocular biometry measurements use ultrasonography and optical biometry, offering high precision for noninvasive intraocular distance measurement in cataract surgery.
Esra ElNaihom
openalex +3 more sources
To compare the refractive outcomes after phacoemulsification with an Intra ocular lens (IOL) using IOL master 700 optical biometer versus conventional ultrasonographic biometer.
Isha Gupta +3 more
openalex +3 more sources
Comment on "Impact of ultrasound and optical biometry on refractive outcomes of cataract surgery after penetrating keratoplasty in keratoconus". [PDF]
Dear Editor, W e read with great interest the article by Krysik et al concerning ultrasound and optical biometry after penetrating keratoplasty (PK) in keratoconus.
De Bernardo M, Cione F, Rosa N.
europepmc +2 more sources
Purpose Precise ocular measurements are fundamental for achieving excellent target refraction following both cataract surgery and refractive lens exchange. Biometry devices with swept-source optical coherence tomography (SS-OCT) employ longer wavelengths
Piotr Kanclerz +2 more
doaj +1 more source
Background Inaccurate biometry can lead to the wrong intraocular lens implantation and result in refractive surprise following cataract surgery. It is important to be sceptical of biometry results that do not match the refractive or clinical picture and ...
Francis Carr, Vinod Gangwani
doaj +1 more source
Eye Biometry Shift after Scleral Buckling Procedure
Background. There are a great number publications presenting results of various types of optical and ultrasound biometry before and after scleral buckling (SB).Patients and methods.
A. N. Kulikov +2 more
doaj +1 more source
Universidade Federal de São Paulo (UNIFESP) Departamento de OftalmologiaUNIFESP, Depto.
Allemann, Norma, Monteiro, Eliana Louza
core +2 more sources
Comparison of ultrasonic pachymetry, with a new optical biometry and tono-pachymetry
The aim of this study was to compare the measurements of central corneal thickness (CCT) using the CT-1P tonopachymetry and AL-Scan optical biometry with those obtained with ultrasound (US) pachymetry. In this prospective study, CCTs were measured in 100
Haci Murat Sagdik +3 more
doaj +1 more source
Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography. [PDF]
PurposeTo assess the interdevice agreement between swept-source Fourier-domain and time-domain anterior segment optical coherence tomography (AS-OCT).MethodsFifty-three eyes from 41 subjects underwent CASIA2 and Visante OCT imaging.
Badr, Mai +6 more
core +2 more sources
Anti-Spoof Reliable Biometry of Fingerprints Using En-Face Optical Coherence Tomography [PDF]
Optical coherence tomography (OCT) is a relatively new imaging technology which can produce high-reso- lution images of three-dimensional structures. OCT has been mainly used for medical applications such as for ophthalmology and dermatology.
Bradu, Adrian +5 more
core +1 more source