Results 191 to 200 of about 9,480,081 (415)

A Python package for fast GPU‐based proton pencil beam dose calculation

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Open‐source GPU‐based Monte Carlo (MC) proton dose calculation algorithms provide high speed and unparalleled accuracy but can be complex to integrate with new applications and remain slower than GPU‐based pencil beam (PB) methods, which sacrifice some physical accuracy for sub‐second plan calculation.
Mahasweta Bhattacharya   +4 more
wiley   +1 more source

Clinical validation of myOSLchip: A beryllium oxide optically stimulated luminescent dosimeter (OSLD) system in radiotherapy dosimetry

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract In radiation oncology, inter‐fractional dosimetry using optically stimulated luminescent detectors (OSLDs) ensures accurate plan delivery and patient safety. RadPro International GmbH's myOLSchip system, featuring a beryllium oxide (BeO) OSL dosimeter, reader, and eraser, was characterized and calibrated with a Varian Truebeam for in‐vivo ...
Heath Davis   +3 more
wiley   +1 more source

Compressive Sensing Theory for Optical Systems Described by a Continuous Model

open access: yes, 2015
A brief survey of the author and collaborators' work in compressive sensing applications to continuous imaging models.Comment: Chapter 3 of "Optical Compressive Imaging" edited by Adrian Stern published by Taylor & Francis ...
Fannjiang, Albert
core  

Optical and UV/x-ray imaging diagnostics for imploding plasma experiments [PDF]

open access: bronze, 1986
P. H. Y. Lee   +7 more
openalex   +1 more source

Evaluation of internal target volume of abdominal tumors using cine‐MRI

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Introduction The detailed anatomy visualization with magnetic resonance (MR)‐guided radiotherapy is particularly attractive for abdominal treatments, but patient respiratory motion can compromise image quality. The “navigator technique” produces high‐quality 3D images, triggered by diaphragm displacement, in exhale phase only.
Jessica Lye   +8 more
wiley   +1 more source

Characterisation of red fluorescent protein FLIM properties and comparison with novel StayGold live cell imaging [PDF]

open access: yesBIO Web of Conferences
Tripal Philipp   +3 more
doaj   +1 more source

Using deep learning generated CBCT contours for online dose assessment of prostate SABR treatments

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Prostate Stereotactic Ablative Body Radiotherapy (SABR) is an ultra‐hypofractionated treatment where small setup errors can lead to higher doses to organs at risk (OARs). Although bowel and bladder preparation protocols reduce inter‐fraction variability, inconsistent patient adherence still results in OAR variability.
Conor Sinclair Smith   +8 more
wiley   +1 more source

Home - About - Disclaimer - Privacy