Results 81 to 90 of about 699 (162)
A Novel Strategy for Improving the Aeromagnetic Compensation Performance of Helicopters
An aeromagnetic survey is an important method in magnetic anomaly detection and geophysical prospecting. The magnetic field is typically measured by optically pumped magnetometers (OPM) installed on the aircraft.
Luzhao Chen +4 more
doaj +1 more source
A plateau in the sensitivity of a compact optically pumped atomic magnetometer
In a compact optically pumped atomic magnetometer (OPAM), there is a plateau in the sensitivity where the dependence of the sensitivity on pumping power is small compared with that predicted by the uniform polarization model. The mechanism that generates
Natsuhiko Mizutani +5 more
doaj +1 more source
Concurrent spinal and brain imaging with optically pumped magnetometers
The spinal cord and its interactions with the brain are fundamental for movement control and somatosensation. However, brain and spinal electrophysiology in humans have largely been treated as distinct enterprises, in part due to the relative inaccessibility of the spinal cord.
Mardell, Lydia C +7 more
openaire +3 more sources
Beyond sensitivity: what are the enabling opportunities of OPM-MEG?
While optically-pumped magnetometer (OPM) technology offers a number of compelling advantages over its SQUID predecessor for magnetoencephalography (MEG), many studies and viewpoints focus on issues of (i) scalp placement, with commensurate increases in ...
Timothy P. L. Roberts +5 more
doaj +1 more source
Measuring Human Auditory Evoked Fields with a Flexible Multi-Channel OPM-Based MEG System
Background: Magnetoencephalography (MEG) is a non-invasive imaging technique for directly measuring the external magnetic field generated from synchronously activated pyramidal neurons in the brain.
Xin Zhang +14 more
doaj +1 more source
An Excitation Circuit of the Cell in Optically Pumped Magnetometer
Cell is the key component in an optically pumped magnetometer. It is necessary to light the cell before measurement and to maintain the illuminated state. The accuracy and stability of magnetic values from the instrument are closely related to the brightness and stability of the cell.
openaire +1 more source
To overcome the shortcoming wherein the accuracy of subsea cable detection can be affected by the determination of the bias vector, scale factors, and non-orthogonality corrections of the vector magnetometer, a real-time attitude-independent route ...
Guozhu Li +7 more
doaj +1 more source
The effect of sensor-to-source distance on magnetic neuromuscular signals
Magnetomyography (MMG) can be used as a contactless modality to study the neuromuscular system. On the one hand, being contactless is a practical advantage as there is no need to prepare skin or attach electrodes as in electromyography (EMG).
Haodi Yang +7 more
doaj +1 more source
Biofunctionalized magnetic nanoparticles (MNPs) have been widely studied for biomedical applications, including magnetic particle imaging (MPI), which is a promising diagnostic technique for cancer imaging.
Teruyoshi Sasayama +2 more
doaj +1 more source
We theoretically analyze an optically spin-polarized collection of atoms, which serves as a basis for atomic sensors. Assuming that the intrinsic atomic spin projection noise is negligible, we provide the closed-form autocorrelation function and the ...
Minwoo M. Kim, Sangkyung Lee
doaj +1 more source

