Results 41 to 50 of about 3,268,766 (203)
Optimal PMU Placement in the Presence of Conventional Measurements
This article presents a novel method for optimal phasor measurement unit placement (OPP) for full power system observability in the presence of conventional measurements. The method considers eligible PMU placements that may be omitted by existing OPP methods and hence may provide a better solution and can guarantee that the PMU placement can restore ...
Zhaoyang Jin +3 more
openaire +1 more source
Optimal PMU location in power systems using MICA
This study presented a modified imperialist competitive algorithm (MICA) for optimal placement of phasor measurement units (PMUs) in normal and contingency conditions of power systems.
Seyed Abbas Taher +2 more
doaj +1 more source
Optimal PMU placement for identification of multiple power line outages in smart grids [PDF]
Placing appropriate numbers of PMUs is critical to collect phase angle data for best identifying multiple line outages in wide-area transmission system, because of high deployment costs.
Yiyu Shi +7 more
core +1 more source
BTLBO Based SPMUs Placement Optimization for Fault Observation in Power Grid
The placement of synchro-phasor measurement units in electric transmission systems has also gained much attention for enhancing the control as well as the protection scheme.
Abdelkader ZITOUNI, Hamid BENTARZI
doaj +1 more source
Optimal co-placement method considering non-homogeneous PMU channel capacities
In this study, a topology defragmentation method is developed for co-placements of phasor measurement units (PMUs) and their communication infrastructure. Electric power networks are defragmented into sets of branches and a realistic cost model, based on
Dahunsi J. Okekunle +2 more
doaj +1 more source
Optimal Placement of Phasor Measurement Unit in Smart Grids Considering Multiple Constraints
The distribution of measurement noise is usually assumed to be Gaussian in the optimal phasor measurement unit (PMU) placement (OPP) problem. However, this is not always accurate in practice.
Tengpeng Chen +4 more
doaj +1 more source
A phasor measurement unit (PMU) can provide phasor measurements to the distribution network to improve observability. Based on pre-configuration and existing measurements, a network compression method is proposed to reduce PMU candidate locations. Taking
Xiangyu Kong +3 more
doaj +1 more source
Widespread deployments of optimally placed real-time power quality (PQ) monitoring tools such as distribution level micro-phasor measurement units (D-PMUs or $\mu $ PMU), digital fault recorders, and PQ analyzers are expected to play a critical role in ...
Manoj Prabhakar Anguswamy +3 more
doaj +1 more source
An antiferroelectric tunnel junction serves as a reservoir computing node, where field‐induced phase transitions and spontaneous ZrO2 relaxation deliver nonlinear fading memory. An In‐Ga‐Zn oxide interlayer enlarges the memory margin and multibit state richness.
Taegyu Kwon +13 more
wiley +1 more source
The current PMU placement model finds the optimal allocation of PMU units in a given network in order to make it observable .The model type is MIP and is applied to a 14,30,57,118 bus IEEE system as described in the following reference:Bei, Xu, Yeo Jun ...
Alireza soroudi (3103971)
core +1 more source