Results 11 to 20 of about 73 (67)
Optimal PMU Placement Considering with HVDC Links and Their Voltage Stability Requirements [PDF]
In wide area measurement systems, PMUs are the main component measuring real time synchronized data from different buses. Installation of PMUs at all buses is a primary way to provide full observability of the power network.
Milad Dalali, Hosein Kazemi Karegar
doaj +1 more source
Phasor Measurement Units (PMUs) are the backbone of smart grids that are able to measure power system observability in real-time. The deployment of synchronized sensors in power networks opens up the advantage of real-time monitoring of the network state.
Nikolaos P. Theodorakatos +2 more
doaj +1 more source
Sensitivity analysis‐based optimal PMU placement for fault observability
This paper proposes an algorithm that finds the optimal sets of phasor measurement units (PMUs) to achieve a fault observable system, while it addresses the multi‐estimation issue.
Pooria Mohammadi +2 more
doaj +1 more source
Optimal Micro-PMU Placement Using Mutual Information Theory in Distribution Networks
Micro-phasor measurement unit (μPMU) is under fast development and becoming more and more important for application in future distribution networks. It is unrealistic and unaffordable to place all buses with μPMUs because of the high costs, leading
Zhi Wu +5 more
doaj +1 more source
Enhanced Optimal PMU Placements With Limited Observability Propagations
When the power grid encounters unexpected contingencies, conventional optimal phasor measurement units (PMUs) placement formulations with unlimited observability propagations may increase the risk of losing the observability.
Xian-Chang Guo +2 more
doaj +1 more source
Optimal PMU location in power systems using MICA
This study presented a modified imperialist competitive algorithm (MICA) for optimal placement of phasor measurement units (PMUs) in normal and contingency conditions of power systems.
Seyed Abbas Taher +2 more
doaj +1 more source
In transforming traditional grid systems into intelligent and microgrid-based systems, the Phasor Measurement Units (PMUs) play a prominent role in enhancing monitoring, assessment, control, and protection by estimating voltage and current phasors ...
Vivekananda Pattanaik +3 more
doaj +1 more source
An Improved OPP Problem Formulation for Distribution Grid Observability
Phasor measurement units (PMUs) are becoming popular and populating the power system grids rapidly due to their wide range of benefits and applications.
Md Shafiullah +3 more
doaj +1 more source
Integer linear programming (ILP) has been widely applied to solve the optimal phasor measurement unit (PMU) placement (OPP) problem for its computational efficiency.
Xuebing Chen +8 more
doaj +1 more source
A phasor measurement unit (PMU) can provide phasor measurements to the distribution network to improve observability. Based on pre-configuration and existing measurements, a network compression method is proposed to reduce PMU candidate locations. Taking
Xiangyu Kong +3 more
doaj +1 more source