Results 1 to 10 of about 3,316 (180)

Improved BPSO for optimal PMU placement [PDF]

open access: yes2015 50th International Universities Power Engineering Conference (UPEC), 2015
Optimal phasor measurement unit (PMU) placement involves the process of minimizing the number of PMU needed while ensuring entire power system network completely observable.
Rahman, NHA, Theodoridis, M, Zobaa, AF
core   +3 more sources

Optimal multistage PMU placement for wide-area monitoring [PDF]

open access: yesIEEE Transactions on Power Systems, 2013
published_or_final_versio
Li, VOK, Wen, H, Xu, J
core   +4 more sources

Enhanced Optimal PMU Placements With Limited Observability Propagations [PDF]

open access: yesIEEE Access, 2020
When the power grid encounters unexpected contingencies, conventional optimal phasor measurement units (PMUs) placement formulations with unlimited observability propagations may increase the risk of losing the observability.
Xian-Chang Guo   +2 more
doaj   +2 more sources

A Critical Review of State-of-the-Art Optimal PMU Placement Techniques

open access: yesEnergies, 2022
Phasor measurement unit (PMU) technology is a need of the power system due to its better resolution than conventional estimation devices used for wide-area monitoring. PMUs can provide synchronized phasor and magnitude of voltage and current measurements
Muhammad Musadiq Ahmed   +5 more
doaj   +3 more sources

Optimal PMU placement using topology transformation method in power systems [PDF]

open access: yesJournal of Advanced Research, 2016
Optimal phasor measurement units (PMUs) placement involves the process of minimizing the number of PMUs needed while ensuring the entire power system completely observable.
Nadia H.A. Rahman, Ahmed F. Zobaa
doaj   +2 more sources

Hierarchical Clustering based optimal PMU placement for power system fault observability [PDF]

open access: yesHeliyon, 2018
Optimal number and location of phasor measurement units (PMUs) in the power system networks faces challenges for achieving the full network observability during fault conditions.
Moustafa Eissa, Amr Kassem
doaj   +2 more sources

An Optimal PMU Placement With Reliable Zero Injection Observation

open access: yesIEEE Access, 2018
Zero injection (ZI) is an inherent characteristic of a power grid. The effect of ZI (ZI effect) is usually utilized as an auxiliary measurement termed ZI observation for simplification. We discover that the ZI observation can transmit. The reliability of
Chengchao Lu   +4 more
doaj   +2 more sources

Tri-Objective Optimal PMU Placement Including Accurate State Estimation: The Case of Distribution Systems

open access: yesIEEE Access, 2021
This paper presents a tri-objective Optimal Phasor Measurement Units (PMUs) Placement (OPP) strategy that is focused on the minimization of i) the total number of PMU channels, ii) the maximum state estimation uncertainty based only on high-rate PMU data
Riccardo Andreoni   +3 more
doaj   +3 more sources

Optimal Placement of PMU to Enhance Supervised Learning-Based Pseudo-Measurement Modelling Accuracy in Distribution Network

open access: yesEnergies, 2021
This paper introduces a framework for optimal placement (OP) of phasor measurement units (PMUs) using metaheuristic algorithms in a distribution network.
Kyung-Yong Lee   +2 more
doaj   +1 more source

On the Computational Viability of Quantum Optimization for PMU Placement [PDF]

open access: yes2020 IEEE Power & Energy Society General Meeting (PESGM), 2020
Using optimal phasor measurement unit placement as a prototypical problem, we assess the computational viability of the current generation D-Wave Systems 2000Q quantum annealer for power systems design problems. We reformulate minimum dominating set for the annealer hardware, solve the reformulation for a standard set of IEEE test systems, and ...
Eric B. Jones   +6 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy