Results 31 to 40 of about 326,663 (289)

Optimizing the roles of unit and non-unit protection methods within DC microgrids [PDF]

open access: yes, 2012
The characteristic behavior of physically compact, multiterminal dc networks under electrical fault conditions can produce demanding protection requirements.
Burt, Graeme   +4 more
core   +1 more source

Analysis and Control of Low-Voltage Ride-Through Capability Improvement for PMSG Based on an NPC Converter Using an Interval Type-2 Fuzzy Logic System

open access: yesElektronika ir Elektrotechnika, 2019
Wind farms must be linked to the grid during the voltage sag. Therefore, the improvement of low-voltage ride-through (LVRT) capability of wind turbine (WT) is a vitally issue. Protection system based on an interval type-2 fuzzy logic system (IT-2 FLC) is
Altan Gencer
doaj   +1 more source

Mine intrinsic safety power supply based on adjustable capacity and protection time

open access: yesMeikuang Anquan, 2021
In view of the contradiction between the capacity and impact resistance of mine intrinsically safe power supply, an intrinsically safe power supply with adjustable capacity and protection time, self-recovery and slow start function is designed.
ZOU Dedong, LIU Peng
doaj   +1 more source

Battery choice and management for New Generation Electric Vehicles [PDF]

open access: yes, 2005
Different types of electric vehicles (EVs) have been recently designed with the aim of solving pollution problems caused by the emission of gasoline-powered engines.
Affanni, A.   +4 more
core   +1 more source

Experimental Modeling of Forward Recovery Characteristics of IGBT for DC Circuit Breaker

open access: yesZhongguo dianli, 2021
DC circuit breaker is the main means to clear the faults in VSC-HVDC power grid. Before action of the hybrid DC circuit breaker, the IGBT in the transfer branch is in a state of zero voltage and zero current.
Hong SHEN   +4 more
doaj   +1 more source

RANCANGAN RELAY PENGAMAN MOTOR INDUKSI BERBASIS FUZZYLOGIC [PDF]

open access: yes, 2011
: A protection relay for 3-phases induction motors hazard protection purpose has been designed utilizing of type A VR AT Mega 32 fuzzy: logic based micro-controller.
Harun, Nadjamuddin   +2 more
core  

Protection strategy for multi-terminal DC networks with fault current blocking capability of converters [PDF]

open access: yes, 2017
High voltage dc networks are a promising technology to flexibly transmit power over long distances. However, dc grid protection is still a major challenge. DC fault clearance can be mainly achieved with three devices. These are ac circuit breakers (ACCBs)
Adamczyk, A.   +5 more
core   +1 more source

Parent Quality of Life at Two Years Following Their Child's Completion of Acute Lymphoblastic Leukemia Treatment

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background Parents of children treated for acute lymphoblastic leukemia (ALL) often experience significant caregiver burden and disruption to their well‐being. While parent quality of life (QoL) during treatment is well characterized, little is known about outcomes during early survivorship.
Sara Dal Pra   +3 more
wiley   +1 more source

Radiation Risks and Mitigation in Electronic Systems [PDF]

open access: yes, 2016
Electrical and electronic systems can be disturbed by radiation-induced effects. In some cases, radiation-induced effects are of a low probability and can be ignored; however, radiation effects must be considered when designing systems that have a high ...
Todd, B., Uznanski, S.
core   +3 more sources

Novel Genetic Risk Factor Identified for L‐Asparaginase‐Induced Pancreatitis in Pediatric Patients With Cancer

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background L‐asparaginase is a critical component in treatment protocols for pediatric acute lymphoblastic leukemia. Acute pancreatitis reactions can necessitate delays and, in some cases, discontinuation of L‐asparaginase, which compromises outcomes.
Edward J. Raack   +39 more
wiley   +1 more source

Home - About - Disclaimer - Privacy