Results 111 to 120 of about 43,414 (164)
Some of the next articles are maybe not open access.
Effect of Distributed Generator on Over Current Relay Behaviour
2020Integration of Distributed Generator (DG) to the distribution network feeder causes its power flow to bidirectional in place of unidirectional influencing the feeder protection. The analysis of chapter presents the influence of Distributed Generator on the over current relay behaviour.
openaire +2 more sources
Application of the Firefly algorithm to optimal over-current relay coordination
2014 International Conference on Optimization of Electrical and Electronic Equipment (OPTIM), 2014Optimization of over current relay settings is a major problem in protection of electrical power systems. This paper describes the Firefly algorithm for optimal time coordination of these relays. The algorithm has been implemented in MATLAB and tested on a radial system, as well as a single end fed system with a parallel feeder. The results obtained by
S. S. Gokhale, V. S. Kale
openaire +1 more source
Improving the performance of smart grid over-current protection relays
2011 IEEE PES Innovative Smart Grid Technologies, 2011Due to the significant increase in non linear loads and the worldwide trend to establish smart grids, harmonic level in the electricity grids is significantly increased. In addition to their impact on power quality, harmonic currents can have a devastating effect on power system protection performance especially on the operation of over current relays ...
Ahmed Abu-Siada +3 more
openaire +1 more source
Microcontrollor Based Over Current Relay for Protection System
2018Microcontrollor Based Over Current Relay for Protection ...
Srinivasan, R., Anisha, Dr. K.
openaire +1 more source
Optimal coordination of over-current relay with Distributed Generation consideration
2011 International Conference on Advanced Power System Automation and Protection, 2011Utilizing Distributed Generation (DG) is greatly increasing in recent years. This is mostly because of simple installation, environmental effects and loss reduction due to closeness to the load centers. However, DG installation, especially in distribution networks, raises some problems. One of these problems is over-current (OC) relays coordination. In
Mehdi Maleknia +1 more
openaire +1 more source
2020 IEEE 9th Power India International Conference (PIICON), 2020
In the presence of distributed generation (DG), the fault current through the relay in forward direction is higher as compared to reverse direction. Thus it is desirable to have dual setting directional over current relay (DOCR) which can operate for both forward and reverse direction of fault current with two independent relay settings.
Raghvendra Tiwari +2 more
openaire +1 more source
In the presence of distributed generation (DG), the fault current through the relay in forward direction is higher as compared to reverse direction. Thus it is desirable to have dual setting directional over current relay (DOCR) which can operate for both forward and reverse direction of fault current with two independent relay settings.
Raghvendra Tiwari +2 more
openaire +1 more source
Optimal coordination of distance and over-current relays using ICA
2014 19th Conference on Electrical Power Distribution Networks (EPDC), 2014Coordination of different relays in transmission systems is an important issue in relays application. In this paper, the over-current and distance relays are coordinated through the Imperialist Competitive Algorithm (ICA) considering time setting multiplier (TSM) and pickup current of the relays.
M. Rahmatian +3 more
openaire +1 more source
Development of line current differential relay over native ethernet
12th IET International Conference on Developments in Power System Protection (DPSP 2014), 2014Packet/frame-based communication services have been in general use for utility communications for a number of years with the exception of communications for protection and in particular line current differential protection. Recently, a number of utilities have begun to investigate the possibility of applying packet/frame-based communication supported ...
S. Fukushima +6 more
openaire +1 more source
Optimal coordination of over-current relays using differential evolution
2012 9th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology, 2012In this paper, the study of optimal coordination of directional over-current relays is proposed. The relay coordination problem is non-linear. It typically consists of two groups of control variables (Time Dial Setting: TDS and Plug Setting: PS). The objective function used is the operation time of the main relay in all considered fault cases.
Somboonsup Rodporn +4 more
openaire +1 more source
2021
Pendistribusian tenaga listrik membutuhkan keandalan dalam menjaga peralatan penyaluran dari gangguan diantaranya gangguan hubung singkat. Untuk meminimalisir gangguan tersebut diperlukan sistem proteksi yang memenuhi persyaratan sensitifitas, keandalan, selektifitas dan kecepatan, yang semuanya tergantung pada ketepatan dalam setting peralatan ...
Paminto, Hany Dwi, Kiswantono, Agus
openaire +1 more source
Pendistribusian tenaga listrik membutuhkan keandalan dalam menjaga peralatan penyaluran dari gangguan diantaranya gangguan hubung singkat. Untuk meminimalisir gangguan tersebut diperlukan sistem proteksi yang memenuhi persyaratan sensitifitas, keandalan, selektifitas dan kecepatan, yang semuanya tergantung pada ketepatan dalam setting peralatan ...
Paminto, Hany Dwi, Kiswantono, Agus
openaire +1 more source