Results 161 to 170 of about 243,473 (208)
Some of the next articles are maybe not open access.

Adiabatic and Overall Effectiveness for a Fully Cooled Turbine Vane

Volume 3B: Heat Transfer, 2013
Adiabatic and overall effectiveness data were measured for a fully cooled, scaled up turbine vane model in a low speed linear cascade with a chord-exit Reynolds number of 700,000. The overall effectiveness is a measure of the external surface temperature relative to the mainstream temperature and the inlet coolant temperature, and consequently is a ...
Thomas E. Dyson   +3 more
openaire   +1 more source

Numerical Investigation on Overall Cooling Effectiveness of Narrow-Channel Double-Wall Cooling

ASME Journal of Heat and Mass Transfer
Abstract In the double-wall cooling of turbine blades, coolant migration can lead to uneven flow distribution, which, in severe cases, can cause hot gas intrusion into the film holes, affecting the lifespan of the blade. To mitigate the negative influence of coolant migration, this study proposes a novel double-wall system called the ...
Guangyao Xu   +4 more
openaire   +1 more source

Overall Cooling Effectiveness on a Flat Plate With Both Film Cooling and Impingement Cooling in Hot Gas Condition

Volume 5A: Heat Transfer, 2016
This paper presents experimental results of temperature distribution on a flat plate with both film cooling and impingement cooling configurations. The film plate consists of 4 rows of round holes injected at an angle of 30°. The impingement plate has a 6×6 jet array.
Bo Shi   +4 more
openaire   +1 more source

Overall Cooling Effectiveness Characteristic and Influence Mechanism on an Endwall With Film Cooling and Impingement

Volume 5A: Heat Transfer, 2015
The cooling system is required to ensure gas turbine can work at high temperature, which has exceeded the material limitation. An endwall cooling test rig was built up to conduct the endwall cooling research. A detailed work was done for analyzing characteristics of endwall heat transfer and discussing the multi-parameter influence mechanism of overall
Mingfei Li   +3 more
openaire   +1 more source

Experimental Study on Analogy Principle of Overall Cooling Effectiveness for Composite Cooling Structures With Both Internal Cooling and Film Cooling

Volume 5A: Heat Transfer, 2019
Abstract The previous theoretical work showed the matching principles of analogy parameters for effusion-impingement cooling model. The mismatch of temperature ratios Tg/Tc may result in different matching performance in laboratory condition.
Gang Xie   +4 more
openaire   +1 more source

Film Cooling on Highly Loaded Blades With Main Flow Separation—Part II: Overall Film Cooling Effectiveness

Journal of Turbomachinery, 2012
Film cooling experiments were run at the high speed cascade wind tunnel of the University of the Federal Armed Forces Munich. The investigations were carried out with a linear cascade of highly loaded turbine blades. The main targets of the tests were to assess the film cooling effectiveness and the heat transfer in zones with main flow separation ...
Reinaldo A. Gomes, Reinhard Niehuis
openaire   +1 more source

Film Cooling on Highly Loaded Blades With Main Flow Separation: Part 2—Overall Film Cooling Effectiveness

Volume 5: Heat Transfer, Parts A and B, 2011
Film cooling experiments were run at the high speed cascade wind tunnel of the University of the Federal Armed Forces Munich. The investigations were carried out with a linear cascade of highly loaded turbine blades. The main targets of the tests were to assess the film cooling effectiveness and the heat transfer in zones with main flow separation ...
Reinaldo A. Gomes, Reinhard Niehuis
openaire   +1 more source

Study on analogy principle of overall cooling effectiveness for composite cooling structures with impingement and effusion

International Journal of Heat and Mass Transfer, 2018
Abstract The overall cooling effectiveness, which represents the distribution of dimensionless temperature on gas turbines surface, is an important parameter for conjugate heat transfer analysis of gas turbines. Generally, it is difficult to measure the overall cooling effectiveness in engine condition.
Cun-liang Liu   +3 more
openaire   +1 more source

Numerical decoupling of the effect of internal cooling and external film cooling on overall cooling effectiveness

Applied Thermal Engineering, 2023
Runzhou Liu   +4 more
openaire   +1 more source

Effects of Internal and Film Cooling on the Overall Effectiveness of a Fully Cooled Turbine Airfoil With Shaped Holes

Volume 5C: Heat Transfer, 2016
Adiabatic and overall effectiveness levels were measured in a closed loop linear test section using an inlet Reynolds number of 120,000 for an airfoil model at its designed inlet angle of −30.1°. Two models were used in the study — one made of a low thermal conductivity foam, and one of a higher thermal conductivity material which allowed for the Biot ...
Kyle Chavez   +2 more
openaire   +1 more source

Home - About - Disclaimer - Privacy