Results 91 to 100 of about 19,321 (267)

High-Voltage IGBT turn-off at transition from overcurrent to desaturation [PDF]

open access: gold, 2021
Weinan Chen   +3 more
openalex   +1 more source

Dissolved Gas Generation Characteristics of Dielectric Liquids Under Partial Discharges and Breakdown Sparks

open access: yesHigh Voltage, Volume 11, Issue 1, Page 233-242, February 2026.
ABSTRACT With the growing interest in monitoring and diagnostic techniques for assessing transformer condition, dissolved gas analysis (DGA) stands out as a crucial diagnostic tool to detect electrical and thermal faults in liquid‐immersed transformers.
Gechen Bian   +3 more
wiley   +1 more source

Overcurrent limiting control with frequency fluctuation suppression under asymmetric faults for voltage source converters

open access: yesInternational Journal of Electrical Power & Energy Systems
Asymmetric faults are a common voltage fault in the power grid, with the rapid development of wind and photovoltaic power generation, grid-connected power generation systems based on voltage source converters (VSCs) will also be affected by asymmetric ...
Andong Liu, Jun Liu
doaj   +1 more source

DC Bus Overcurrent Protection Scheme in Metro DC Traction Power Supply System Based on Boolean Logic Calculation

open access: yesChengshi guidao jiaotong yanjiu
[Objective] To enable accurate determination of DC (direct current) bus overcurrent protection in metro DC traction power supply system and enhance the selectivity of fault tripping in the system, the research on a suitable DC bus overcurrent protection ...
LIU Yuxing   +5 more
doaj   +1 more source

Inverter-converter automatic paralleling and protection [PDF]

open access: yes
Electric control and protection circuits for parallel operation of inverter ...
Doughman, C. L.   +2 more
core   +1 more source

Review on Coordination of Time Overcurrent Relays in Electrical Distribution Network

open access: yesActa Technica Jaurinensis
Integration of distributed generators in micro grid causes bidirectional current flow as a result of the need for readjustment of the setting of the overcurrent protective relays in the electrical network.
Godfrey Mhagama   +2 more
doaj   +1 more source

Arcing High Impedance Fault Detection Using Real Coded Genetic Algorithm

open access: yes, 2007
Safety and reliability are two of the most important aspects of electric power supply systems. Sensitivity and robustness to detect and isolate faults can influence the safety and reliability of such systems.
Al-Othman, A.K.   +2 more
core  

Laboratory testing of the communication based protection relays [PDF]

open access: yes, 2015
The proper operation of control and protection applications in Substation Automation System (SAS) demands very high-speed and reliable communications that has being achieved by using IEC 61850.
Daboul, M., Wasserbauer, V.
core  