Results 81 to 90 of about 19,321 (267)
Circuit provides overcurrent protection to push-pull amplifier [PDF]
Circuit in push-pull amplifier limits the current flowing to a predetermined level and provides that overcurrent in one half of the amplifier turns off the other ...
Skorra, D. J.
core +1 more source
Enhancing Q‐Learning via State‐Space Design for Active Battery Balancing
This study investigates the profound impact of state definition on the efficacy of Q‐learning for active battery balancing in lithium‐ion battery packs. We define and evaluate three distinct state representations—[State 1, 11‐state space definition], [State 2, 27‐state space definition], and [State 3, 81‐state space definition]—within a reinforcement ...
Fatemeh Ebrahimabadi +2 more
wiley +1 more source
High-power ac/dc variable load simulator [PDF]
Design of medium-power dynamic electrical load simulator has been extended to permit simulation of ac as well as dc loads and to provide for operation at higher power levels.
Birnbach, S. +3 more
core +1 more source
Power balancing and dc fault ride through in DC grids with dc hubs and wind farms [PDF]
Acknowledgment This project was funded by European Research Council under the Ideas program in FP7; grant no 259328, 2010.Peer ...
Jovcic, Dragan, Lin, Weixing
core +1 more source
Proposed active rectifier solution, detailing the high‐side and low‐side power switch control circuit for implementing the active diodes. ABSTRACT This paper proposes a novel active rectifier architecture for wireless power transfer (WPT) systems. In addition to performing rectification, the proposed structure features embedded current monitoring ...
Elisabetta Moisello +3 more
wiley +1 more source
This paper proposes a doubly fed induction generator rotor voltage compensation control to address transient voltage dips in renewable‐rich grids. By compensating for rotor electromotive forces, it suppresses current fluctuations and surges during asymmetrical faults.
Xiaoning Li +4 more
wiley +1 more source
Assessing the reliability of adaptive power system protection schemes [PDF]
Adaptive power system protection can be used to improve the performance of existing protection schemes under certain network conditions. However, their deployment in the field is impeded by their perceived inferior reliability compared to existing ...
Abdulhadi, Ibrahim Faiek +3 more
core +1 more source
Busbar Fault Direction Identification Using Sequences of Displacement Vectors
In this paper, a novel busbar fault direction identification scheme is presented. The proposed scheme is based on sequences of displacement vectors. The proposed algorithm is fast and simple enough to be embedded in a differential relay to assist the percentage‐restraint differential algorithm.
Mostafa Sarlak
wiley +1 more source
The optimal setting of directional overcurrent relays ensures the reliable protection and fast fault clearance of radial distribution networks. However, the increasing proliferation of inverter-based distributed energy resources can result in protection ...
Jie Li +4 more
doaj +1 more source
As the development of renewable distributed generations (DGs) is growing rapidly, the autonomous self-healing microgrid had emerged as an effective solution for integrating renewable DGs in the distribution networks.
Kheng Heong Oon +4 more
doaj +1 more source

