Results 11 to 20 of about 3,412 (219)
Enhanced Transformer Overcurrent Protection via Oil Temperature Acceleration
When a transformer is in a long-term heavy load operation state, the oil temperature reaches the alarm temperature; if a slight fault occurs inside the transformer, traditional inverse time current protection and other protections that react to phase ...
Qingguo Liu +4 more
doaj +2 more sources
Performance Evaluation of Overcurrent Protection Relay Based on Relay Operation Time (ROT)
Protection system plays an important role in detecting the presence of disorders and may prevent damage that can caused interference. Thus, the reliability of the system to maintain continuity of supply to the load will be improved.
Mohd Hendra Hairi +3 more
doaj +4 more sources
Systems of Electronic Overcurrent Protection in Pulse Power Generator Operating on Plasma Load
Schematic peculiarities of pulsed power source and modulator-shaper for working on high instability plasma load are discussed. In its construction should be provided for several levels of overcurrent protection.
Dmitriy V. Godun +2 more
doaj +3 more sources
Influence of Excitation Mode Difference on RAM Generator Overcurrent Protection Setting
The rotating asynchronous machine (RAM) system in the power stations of China General Nuclear Power Group (CGN) includes three types of generators —i.e., Shangdian generator, Zhongchuan generator and Remeng generator.
Runpei LI +4 more
doaj +1 more source
Overcurrent and Directional Overcurrent Protection for Microgrid
Microgrids will become common in future electrical distribution networks. Numerous operating modes that occur in microgrids make the development of protection schemes and settings challenging. This paper aims to develop a simple protection scheme for the Microgrid IEC Benchmark without any expensive equipment such as communication apparatus.
Zahira Shiva Salsabila +2 more
openaire +1 more source
An Optimization-based Protection Strategy in Active Distribution Network using Double Dual-Setting Directional Overcurrent Relays to Increase DG Penetration [PDF]
Coordination between protection devices is one of the important issues in any protection scheme of an electrical power system. The tendency to increasingly use distributed generation has jeopardized the selectivity of overcurrent relays in active ...
Sajjad Dadfar, Shokoofeh Balooch
doaj +1 more source
The hybridization of PSO for the Optimal Coordination of Directional Overcurrent Protection Relays (DOPR) of the IEEE bus system proposes a new method for coordinating directional overcurrent protection relays in power systems.
Yuheng Wang +3 more
doaj +1 more source
The safe and reliable operation of a distribution network (DN) is closely related to the development of national economy and the improvement of people's living standards.
Qun Ge +3 more
doaj +1 more source
Influence of the converter transformer valve-side bushing fault on commutation reactance protection and improvement scheme [PDF]
Commutation reactance is an important component in the voltage-source converter- based high-voltage direct current (VSC–HVDC) transmission system. Due to its connection to the converter, when there is a fault occurring on the valve-side bushing of a ...
Yanxia Zhang +4 more
doaj +1 more source
Protection schemes are essential in active distribution networks and microgrids’ reliable, efficient, and flexible operation. However, the protection of these networks presents significant challenges due to operational changes, such as variations ...
Adrian Barranco-Carlos +4 more