Results 21 to 30 of about 1,016 (180)
Variance‐Empirical Mode Decomposition Method for Fault Detection in MMC‐HVDC Transmission Lines
A variance‐embedded empirical mode decomposition (VEMD) method is proposed for fast and accurate fault detection in MMC‐HVDC transmission lines. By combining variance analysis with EMD, the method reliably detects various faults without communication links and remains robust to noise and non‐fault transients.
Seyed Amir Hosseini, Behrooz Taheri
wiley +1 more source
A Novel Method for Overcurrent Protection of Outlet Line Connecting BESS Considering Battery SOC
Due to the influence of the control strategy of the battery energy storage station (BESS), the degree of voltage sag, and the battery state of charge (SOC), the fault current characteristics of the BESS outlet line differ significantly.
Bin Wu +5 more
doaj +1 more source
A real‐time power quality disturbance generator is developed using virtual instrumentation based on LabVIEW and NI MyDAQ. The system generates IEEE‐standard PQ events with controllable noise and harmonics. Measurement uncertainty analysis confirms its reliability for realistic testing of Power Quality Disturbance detection and classification algorithms.
Abdullah Saud +5 more
wiley +1 more source
[Objective] To enable accurate determination of DC (direct current) bus overcurrent protection in metro DC traction power supply system and enhance the selectivity of fault tripping in the system, the research on a suitable DC bus overcurrent protection ...
LIU Yuxing +5 more
doaj +1 more source
Comprehensive protection scheme for lines with unmeasurable branches based on 5G channels
There are many unmeasurable branches along with distribution lines. The sensitivity and speed of traditional three-stage overcurrent protection lacks when applied to these lines.
ZHANG Jinhu +5 more
doaj +1 more source
ABSTRACT This paper investigates the generation mechanism of quasi‐power‐frequency resonant overvoltage triggered by multiple lightning strikes in high‐voltage alternating current (HVAC) systems equipped with shunt reactors. Based on field measurements from a 500 kV AC system, equivalent and simplified circuit models have been established to analyse ...
Tao Liang +7 more
wiley +1 more source
This work reports a thermally safe, photothermally reprogrammable magnetic soft robot with its reprogramming temperature tuned to ∼39.5°C for biocompatibility. It achieves multimodal locomotion (max speed of 1.8 BL/s) and integrates liquid‐metal capacitive sensing to monitor self‐motion and detect environmental changes in simulated gastric environments,
Liu Yang +5 more
wiley +1 more source
The optimal setting of directional overcurrent relays ensures the reliable protection and fast fault clearance of radial distribution networks. However, the increasing proliferation of inverter-based distributed energy resources can result in protection ...
Jie Li +4 more
doaj +1 more source
By manipulating current and voltage measurements, an assailant can induce unwanted relay action while attempting to avoid detection. Detecting advanced cyber intrusions in power protection environments requires specialised data analysis and anomaly detection methods.
Feras Alasali +6 more
wiley +1 more source
A Review of Failure Modes and Safety Strategies of Lithium‐Ion Batteries from Materials to Systems
A cascade‐aware framework is presented for lithium‐ion battery safety, linking thermal runaway initiation, acceleration, runaway reaction, and propagation with material‐, cell/pack‐, and system‐level interventions. By integrating failure mechanisms, quantitative safety indicators, and staged interception strategies, this review highlights how safer ...
Jin Hyeok Yang +8 more
wiley +1 more source