Results 81 to 90 of about 11,997 (226)

Breakdown Characteristics of PEEK Insulation Immersed in Synthetic Ester Liquid for Subsea Cable Connectors

open access: yesElectrical Materials and Applications, Volume 3, Issue 1, January/December 2026.
This paper proposes integrating polyether ether ketone (PEEK) with a synthetic ester liquid as the composite insulation system for subsea cable connectors. The study commences with a comparative analysis of the electrical performance of PEEK when immersed in a synthetic ester liquid and a mineral oil.
Danny Guana   +3 more
wiley   +1 more source

Application of Under-Impedance Criterion to Protect against Effects of Phase-to-Phase Short Circuits in Medium-Voltage Networks

open access: yesEnergies
Common overcurrent criteria used to detect phase-to-phase short circuits in medium-voltage (MV) networks in some cases do not bring the expected results.
Beata ZiÄ™ba   +2 more
doaj   +1 more source

Impact Assessment of Hypothesized Cyberattacks on Interconnected Bulk Power Systems

open access: yes, 2018
The first-ever Ukraine cyberattack on power grid has proven its devastation by hacking into their critical cyber assets. With administrative privileges accessing substation networks/local control centers, one intelligent way of coordinated cyberattacks ...
Ginter, Andrew   +4 more
core   +1 more source

Distance Protection for Microgrids in Distribution System [PDF]

open access: yes, 2015
Owing to the increasing penetration of distributed generation, there are some challenges for the conventional protection in distribution system. Bidirectional power flow and variable fault current because of the various operation modes may lead to the ...
Guerrero, Josep M.   +3 more
core   +2 more sources

Pengembangan Sistem Proteksi Digital Arus Lebih Berbasis Logika Fuzzy sebagai Pengaman PLTMH

open access: yesJurnal Nasional Teknik Elektro, 2013
In this paper discussed digital overcurrent protection system fuzzy logic on plant systems or Micro Hydro Power Plants with fuzzy logic approach to the identification of the signal changes due to interference overcurrent short circuit the lifeboat ...
Cahayahati   +3 more
doaj  

Enhanced Transformer Overcurrent Protection via Oil Temperature Acceleration

open access: yesEnergies
When a transformer is in a long-term heavy load operation state, the oil temperature reaches the alarm temperature; if a slight fault occurs inside the transformer, traditional inverse time current protection and other protections that react to phase ...
Qingguo Liu   +4 more
doaj   +1 more source

Systems of Electronic Overcurrent Protection in Pulse Power Generator Operating on Plasma Load [PDF]

open access: yes, 2017
Schematic peculiarities of pulsed power source and modulator-shaper for working on high instability plasma load are discussed. In its construction should be provided for several levels of overcurrent protection.
Bordusov , Sergey. V.   +2 more
core  

Inverter-converter automatic paralleling and protection [PDF]

open access: yes
Electric control and protection circuits for parallel operation of inverter ...
Doughman, C. L.   +2 more
core   +1 more source

A novel overcurrent protection method based on wide area measurement in smart grid [PDF]

open access: yes, 2013
PowerTech is the anchor conference of the IEEE Power & Energy Society in EuropeConventional overcurrent protection settings are fixed to detect faults. Power system operation mode varies while the settings of protection devices remain constant.
Jing, X, Lin, SH, Zhan, CL, Zhong, J
core   +1 more source

Guidelines for Protection against Overcurrent in Photovoltaic Generators

open access: yesAdvances in Electrical and Computer Engineering, 2012
This paper gives the scientific background and basic premises that should guide the design of overcurrent protection in photovoltaic generators (PVGs).
GARCIA, O., HERNANDEZ, J.-C., JURADO, F.
doaj   +1 more source

Home - About - Disclaimer - Privacy