Results 211 to 220 of about 6,985 (272)
Improving the Protection of Step-Down Transformers by Utilizing Percentage Differential Protection and Scale-Dependent Intrinsic Entropy. [PDF]
Huang CW +4 more
europepmc +1 more source
Field Programmable Gate Array-Based Smart Switch to Avoid Inrush Current in PV Installations. [PDF]
Martínez-Figueroa GJ +2 more
europepmc +1 more source
Effectiveness of supervised machine learning models for electrical fault detection in solar PV systems. [PDF]
Khandeparkar V, Shreshtha, Ramu SK.
europepmc +1 more source
Some of the next articles are maybe not open access.
Related searches:
Related searches:
IEEE Transactions on Power Delivery, 2011
In this paper, a new objective function (OF) within the genetic algorithm (GA) approach is presented to solve the optimization problem of coordination of overcurrent and distance relays. The existing objective function of overcurrent (O/C) relays coordination is improved and extended to include the coordination of O/C and distance relays.
Reza Mohammadi Chabanloo +2 more
exaly +2 more sources
In this paper, a new objective function (OF) within the genetic algorithm (GA) approach is presented to solve the optimization problem of coordination of overcurrent and distance relays. The existing objective function of overcurrent (O/C) relays coordination is improved and extended to include the coordination of O/C and distance relays.
Reza Mohammadi Chabanloo +2 more
exaly +2 more sources
Microprocessor-Based Overcurrent Relays
IEEE Transactions on Industrial Electronics, 1986Inverse overcurrent is normally associated with the overcurrent relay types, the operation time is inversely proportional (in certain degrees) with their overcurrent ratio.
Mudhafar A. Al-Nema +2 more
exaly +2 more sources
The Universal Overcurrent Relay
IEEE Industry Applications Magazine, 1996A comprehensive list of nondirectional overcurrent relays would include thermal overload, inverse-time, definite time, and instantaneous relays. The list could be further classified by operating quantities including individual phase, residual, and negative-sequence current.
E. O. Schweitzer, S. E. Zocholl
openaire +1 more source
Electric Power Systems Research, 1996
Abstract This paper presents the design and construction of overcurrent and directional overcurrent relays with ground fault protection for the protection of three-phase subtransmission and distribution systems, using a 16-bit microprocessor, the Intel 8096BH. The relay obtains the system currents at the rate of 12 samples per cycle and estimates the
Zhijun, G., Elangovan, S., Liew, A.C.
openaire +1 more source
Abstract This paper presents the design and construction of overcurrent and directional overcurrent relays with ground fault protection for the protection of three-phase subtransmission and distribution systems, using a 16-bit microprocessor, the Intel 8096BH. The relay obtains the system currents at the rate of 12 samples per cycle and estimates the
Zhijun, G., Elangovan, S., Liew, A.C.
openaire +1 more source

