HVDC cable systems connected to HVDC overhead lines are subject to fast front overvoltages emanating from the line when lightning strikes a shield wire (backflashover) or a pole conductor (shielding failure).
Oscar Lennerhag +4 more
doaj +3 more sources
Improve hardware facilities and work algorithms of overhead contact line remote monitoring systems [PDF]
An autonomous diagnostic measuring device, that allows to reduce expenses for the maintenance and the need for highly qualified personnel, is proposed in the article.
Smerdin Aleksandr +3 more
doaj +1 more source
Characteristics of lightning‐induced voltages based on experimental data
This paper presents an analysis of 64 lightning‐induced voltage waveforms recorded in an experimental system implemented in the campus of the University of São Paulo, Brazil.
Michele N. N. Santos, Alexandre Piantini
doaj +1 more source
On-line Monitoring of Sag and Icing of Overhead Transmission Lines
In order to realize on-line icing and galloping monitoring of overhead transmission lines, an on-line monitoring method for overhead transmission lines based on phase-sensitive optical time domain reflectometry (Φ-OTDR) is proposed.
YANG Xiaolong +4 more
doaj +1 more source
The electrical grid of regional power systems primarily uses double-circuit 220 kV overhead power lines to function. This paper provides information on the problem of ice formation on overhead ground wires of 220 kV power lines, including a brief ...
Krotkov E.A. +2 more
doaj +1 more source
Nonintrusive overhead‐line current detection using a vertical magnetic‐field sensor array
With the growing infrastructure for overhead lines, the demand for overhead‐line condition‐monitoring technologies has become increasingly urgent. Traditional current transformers used to measure three‐phase currents are bulky and difficult to install ...
Kun‐Long Chen +2 more
doaj +1 more source
Influence of contact gaps on the conditions of vehicles supply and wear and tear of catenary wires in a 3 kV DC traction system [PDF]
Short-term contact losses between a pantograph and a contact wire are not included in the standards nor are they taken into account in evaluating pantograph-contact wire interaction.
T. Maciołek +3 more
doaj +1 more source
Evaluation of the Idle time of Single-Chain and Double-Chain Overhead Power Lines of 6–10 kV by Methods of Queuing Theory [PDF]
The aim of this work is to substantiate the idle time evaluation of the overhead power line (OPL) according to the reliability indicators of its main elements using the probability value of the overhead power line availability factor. Statistical studies
Basmanov V.G., Kholmanskikh V.M.
doaj +1 more source
Research on Overhead Line Cost Prediction Based on Index Construction [PDF]
In order to meet the growing demand of the society for electric power, the construction of electric power infrastructure is constantly carried out. However, investment in construction and cost control are particularly important.
He Yongping +4 more
doaj +1 more source
Normalization of double-circuit overhead line magnetic field inside Khrushchev building
This paper deals with the mitigation of 110 kV double-circuit overhead line magnetic field inside five-story Khrushchev buildings. We show that the magnetic field can exceed the reference level 0.5 μT in 90 % part of living space.
K. V. Chunikhin, V. S. Grinchenko
doaj +1 more source

