Results 1 to 10 of about 191,382 (211)
In this paper, the effectiveness of lightning overvoltage protection of cables in high voltage overhead cable lines has been analyzed. Because of the high overvoltage level, the cables are protected by surge arresters and by metallic sheath earthing ...
Wieslaw Nowak +2 more
exaly +2 more sources
The current transformer (CT) harvester is effective and efficient for energy harvesting on overhead lines due to its higher reliability and power density compared to other techniques.
Zhongnan Qian +2 more
exaly +2 more sources
Atmospheric Sensors and Energy Harvesters on Overhead Power Lines [PDF]
We demonstrate the feasibility of using novel, small energy harvesters to power atmospheric sensors and radios simply attached to a single conductor of existing overhead power distribution lines. We demonstrate the ability to harvest the required power for operating multiple atmospheric and power-system sensors, together with short-range radios that ...
Zhiwei Wu, Richard M White
exaly +3 more sources
Influence of Ambient Temperature on the Reliability of Overhead LV Power Lines with Bare Conductors
The article presents a study on the influence of weather factors (ambient temperature) on the operational reliability of overhead low-voltage power lines with bare conductors.
Kornelia Banasik
doaj +3 more sources
A distributed optical fiber sensor based on Brillouin scattering can measure the strain along the optical fiber. In order to improve the real-time performance of strain measurement for optic-electric composite overhead lines in the distribution Internet ...
Chao Jiang +2 more
semanticscholar +1 more source
Method for Calculating of Lightning Impact Level on Overhead Transmission Line
This paper proposes a simple method for calculating the lightning impact level on overhead transmission power lines, taking into account its entire length. The method uses lightning historical data and the geographic coordinates of power line towers.
Anton Vladimirovich Burtsev +1 more
doaj +1 more source
Introduction. The problem of estimating power losses in grounding wires with built-in fiber optic cable for overhead power lines of voltage class 330-750 kV is relevant, while it is obvious that the amount of losses depends on the chosen brand of wire ...
A. V. Krasnozhon +4 more
doaj +1 more source
Characteristics of lightning‐induced voltages based on experimental data
This paper presents an analysis of 64 lightning‐induced voltage waveforms recorded in an experimental system implemented in the campus of the University of São Paulo, Brazil.
Michele N. N. Santos, Alexandre Piantini
doaj +1 more source
Fault detection through discrete wavelet transform in overhead power transmission lines
Transmission lines are a very important and vulnerable part of the power system. Power supply to the consumers depends on the fault‐free status of transmission lines.
Nadeem Ahmed +4 more
semanticscholar +1 more source
The electrical grid of regional power systems primarily uses double-circuit 220 kV overhead power lines to function. This paper provides information on the problem of ice formation on overhead ground wires of 220 kV power lines, including a brief ...
Krotkov E.A. +2 more
doaj +1 more source