Results 221 to 230 of about 111,551 (360)

Increased Borrelia burgdorferi Seroprevalence in Nova Scotia—Prevalence and Distribution 10 Years Later

open access: yesZoonoses and Public Health, EarlyView.
ABSTRACT Lyme disease (LD), a tick‐borne infection, is endemic in Nova Scotia. One decade ago, the seropositivity rate to Borrelia burgdorferi was 2/1855 (0.14%). In the current study, using residual sera representing ages 10–64 years, we demonstrate an increase in seroprevalence, to 25/1872 (1.60%), with the highest seroprevalence in the western area ...
Carrie Phillips   +10 more
wiley   +1 more source

Pyrene‐Conjugated, 2‐Pyridinecarboxaldehyde Derivatives as N‐Terminus‐Specific Tags for MALDI‐ and LALDI‐MS

open access: yesRapid Communications in Mass Spectrometry, Volume 40, Issue 8, 30 April 2026.
ABSTRACT Background Proteolytic processing is a fundamental post‐translational modification. Liquid chromatography–tandem mass spectrometry (LC–MS/MS) workflows are powerful for degradomic analyses but inherently sacrifice spatial information, a critical aspect for investigating biological systems such as aberrant extracellular matrix remodeling and ...
Mujia Jenny Li   +8 more
wiley   +1 more source

82.5 GHz Photonic W-Band IM/DD PS-PAM4 Wireless Transmission over 300 m Based on Balanced and Lightweight DNN Equalizer Cascaded with Clustering Algorithm. [PDF]

open access: yesSensors (Basel)
Ge J   +14 more
europepmc   +1 more source

Open‐Source Simulator of Imaging Near Metal at Arbitrary Magnetic Field Strengths

open access: yesMagnetic Resonance in Medicine, Volume 95, Issue 4, Page 2370-2383, April 2026.
ABSTRACT Purpose The increasing prevalence of orthopedic metallic implants necessitates optimization of MRI methods to monitor surrounding tissues and identify complications. The emergence of contemporary mid‐ and low‐field systems as promising platforms for imaging around metal requires development of new protocols optimized for these field strengths.
Kübra Keskin   +3 more
wiley   +1 more source

Automatic Respiratory and Bulk Patient Motion Corrected 3D Fetal MRI

open access: yesMagnetic Resonance in Medicine, Volume 95, Issue 4, Page 1972-1985, April 2026.
ABSTRACT Purpose To develop a framework (ACROBATIC) for correcting motion in 3D radial fetal MRI. Methods Data were simulated (N = 200) and acquired in utero (N = 11, gestational age: 32 ± 2 weeks). Motion due to maternal respiration was estimated by extracting a self‐gating signal and applying focused navigation. Bulk motion was estimated by splitting
Robin Ferincz   +8 more
wiley   +1 more source