Impact of ICD Presence in Patients With Left Ventricular Assist Devices for End‐Stage Heart Failure
ABSTRACT Background The prognostic relevance of implantable cardioverter defibrillator (ICD) in patients with end‐stage heart failure (HF) with left ventricular assist device (LVAD) remains controversial. Objectives To evaluate the prognostic impact of ongoing use of ICD and associated complications in HF‐patients with LVAD‐implantation.
Nafilah Baridwan +11 more
wiley +1 more source
ABSTRACT An 88‐year‐old pacemaker‐dependent man with a retained low‐impedance, noise‐producing right ventricular lead underwent implantation of a dual‐chamber leadless pacemaker. On postoperative day 1, he developed recurrent syncope with pauses up to 13 s.
Yuya Nakamura +5 more
wiley +1 more source
Device rounds: T-wave oversensing: A cause of loss of cardiac resynchronization therapy
A CRT-D patient presented with loss of biventricular pacing associated with heart failure symptoms. The electrocardiogram showed sinus rhythm with alternating wide unpaced and narrower paced QRS complexes.
Nicolas B. Dayal, Haran Burri
doaj +1 more source
A 65-year-old gentleman with dual chamber pacemaker presented with presyncope. The ECG raised concerns of oversensing which was confirmed by magnet response. The device interrogation revealed noise in ventricular channel temporally associated with P wave.
Debabrata Bera +3 more
doaj +1 more source
Safety of Pulsed Field Ablation: Established Evidence, Emerging Risks, and Knowledge Gaps
Overview of the safety profile of pulsed field ablation (PFA), highlighting established safety advantages, procedure‐related complications, electroporation‐specific effects, and key areas of ongoing uncertainty, particularly for ventricular applications.
Dakota de Cecco +3 more
wiley +1 more source
A Fortuitous Syncope. The pitfalls of Integrated Bipolar Defibrillator Leads
Myopotential oversensing in implantable defibrillators causing inhibition of pacing and inappropriate therapies is well described. Current literature is dominated by reports of diaphragmatic muscle as the source of such far-field oversensing.
Tushar V Salukhe +4 more
doaj
Ventricular asystole due to atrial oversensing by a VVI pacemaker: VVT mode as a simple solution
We report a rare case of atrial oversensing by a VVI pacemaker that caused ventricular asystole. Changing the programming to VVT mode not only eliminated the problem but also provided atrioventricular synchrony and rate responsiveness.
Kazushi Tanaka, Osamu Fujimura
doaj +1 more source
This statement of the Japanese Heart Rhythm Society (JHRS) provides comprehensive guidance for medical professionals and device manufacturers involved in RM. ABSTRACT Remote monitoring (RM) has been established as a standard tool for the management of patients with cardiac implantable electronic devices (CIEDs), offering advantages such as early event ...
Eiichi Watanabe +10 more
wiley +1 more source
A 60‐year‐old male experienced an inappropriate shock from an implantable cardioverter‐defibrillator (ICD) because of oversensing of pectoral myopotentials. Battery depletion was also observed, and a generator change was performed.
Yuichi Hori +6 more
doaj +1 more source
We experienced 2 cases in which oversensing of a particular noise after the implantation of an implantable cardiac device was observed in the acute phase.
Shigeyuki Okahara +8 more
doaj +1 more source