Impact of ICD Presence in Patients With Left Ventricular Assist Devices for End‐Stage Heart Failure

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background The prognostic relevance of implantable cardioverter defibrillator (ICD) in patients with end‐stage heart failure (HF) with left ventricular assist device (LVAD) remains controversial. Objectives To evaluate the prognostic impact of ongoing use of ICD and associated complications in HF‐patients with LVAD‐implantation.
Nafilah Baridwan   +11 more
wiley   +1 more source

Ventricular Pacing Inhibition After Dual‐Chamber Leadless Pacing Associated With a Retained Right Ventricular Lead

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT An 88‐year‐old pacemaker‐dependent man with a retained low‐impedance, noise‐producing right ventricular lead underwent implantation of a dual‐chamber leadless pacemaker. On postoperative day 1, he developed recurrent syncope with pauses up to 13 s.
Yuya Nakamura   +5 more
wiley   +1 more source

Device rounds: T-wave oversensing: A cause of loss of cardiac resynchronization therapy

open access: yesIndian Pacing and Electrophysiology Journal, 2016
A CRT-D patient presented with loss of biventricular pacing associated with heart failure symptoms. The electrocardiogram showed sinus rhythm with alternating wide unpaced and narrower paced QRS complexes.
Nicolas B. Dayal, Haran Burri
doaj   +1 more source

Inhibition of ventricular output in a dual chamber pacemaker with normal pacing and sensing parameters: What is the mechanism?

open access: yesIndian Pacing and Electrophysiology Journal, 2022
A 65-year-old gentleman with dual chamber pacemaker presented with presyncope. The ECG raised concerns of oversensing which was confirmed by magnet response. The device interrogation revealed noise in ventricular channel temporally associated with P wave.
Debabrata Bera   +3 more
doaj   +1 more source

Safety of Pulsed Field Ablation: Established Evidence, Emerging Risks, and Knowledge Gaps

open access: yesPacing and Clinical Electrophysiology, EarlyView.
Overview of the safety profile of pulsed field ablation (PFA), highlighting established safety advantages, procedure‐related complications, electroporation‐specific effects, and key areas of ongoing uncertainty, particularly for ventricular applications.
Dakota de Cecco   +3 more
wiley   +1 more source

A Fortuitous Syncope. The pitfalls of Integrated Bipolar Defibrillator Leads

open access: yesIndian Pacing and Electrophysiology Journal, 2008
Myopotential oversensing in implantable defibrillators causing inhibition of pacing and inappropriate therapies is well described. Current literature is dominated by reports of diaphragmatic muscle as the source of such far-field oversensing.
Tushar V Salukhe   +4 more
doaj  

Ventricular asystole due to atrial oversensing by a VVI pacemaker: VVT mode as a simple solution

open access: yesJournal of Arrhythmia, 2012
We report a rare case of atrial oversensing by a VVI pacemaker that caused ventricular asystole. Changing the programming to VVT mode not only eliminated the problem but also provided atrioventricular synchrony and rate responsiveness.
Kazushi Tanaka, Osamu Fujimura
doaj   +1 more source

Expert Consensus Statement: Committee on Implantable Devices and Committee on Social Issues, Japanese Heart Rhythm Society (JHRS) Statement on Remote Monitoring of Cardiac Implantable Electronic Devices

open access: yesJournal of Arrhythmia, Volume 42, Issue 5, October 2026.
This statement of the Japanese Heart Rhythm Society (JHRS) provides comprehensive guidance for medical professionals and device manufacturers involved in RM. ABSTRACT Remote monitoring (RM) has been established as a standard tool for the management of patients with cardiac implantable electronic devices (CIEDs), offering advantages such as early event ...
Eiichi Watanabe   +10 more
wiley   +1 more source

Limitation of the bandpass filter in preventing oversensing of pectoral myopotentials over the long‐term follow‐up

open access: yesJournal of Arrhythmia, 2018
A 60‐year‐old male experienced an inappropriate shock from an implantable cardioverter‐defibrillator (ICD) because of oversensing of pectoral myopotentials. Battery depletion was also observed, and a generator change was performed.
Yuichi Hori   +6 more
doaj   +1 more source

Oversensing of a Particular Transient Noise Appearing After the Implantation of an Implantable Cardiac Device

open access: yesJournal of Arrhythmia, 2011
We experienced 2 cases in which oversensing of a particular noise after the implantation of an implantable cardiac device was observed in the acute phase.
Shigeyuki Okahara   +8 more
doaj   +1 more source