Results 91 to 100 of about 2,108,671 (167)

Overvoltage protection network [PDF]

open access: yes, 1974
Electrical equipment to be protected from overvoltage is connected with a possible source of overvoltage via an input conductor. A fuse is connected in series with the input conductor.
Cambra, J. M.
core  

RISK EVALUATION IN LIGHTNING AND OVERVOLTAGE PROTECTION [PDF]

open access: yes, 2000
With the development of electronics several tendencies whose joint emergence redoubles the significance of damages to electronic parts is visible simultaneously today.
Tatár, Dénes
core   +1 more source

Design of Fault Protection Stra for Unified Power Flow Controller in Distribution Networks

open access: yesEnergies
The capacity of traditional distribution networks is limited. After large-scale distributed power sources are connected, it is difficult to consume them at the same voltage level, which can lead to transformer reverse overloading and voltage limit ...
Xiaochun Mou   +6 more
doaj   +1 more source

Overvoltage protection for low voltage equipment

open access: yes, 2013
Předkládaná diplomová práce je zaměřena na přepěťové ochrany nízkého napětí s použitím při ochraně budov, instalací, fotovoltaických elektráren, datových i anténních zařízeních v oblasti nízkého napětí.
Živný, Jiří
core  

Necessity of overvoltage protection studies for gas-insulated switchgear [PDF]

open access: yes, 2017
Kaasueristeisten kytkinlaitosten määrä kantaverkossa lisääntyy tulevaisuudessa merkittävästi erityisesti korvausrakentamisen myötä. Kaasueristeinen kojeisto on herkkä ylijännitteille ja aiheuttaa vikaantuessaan pitkän keskeytyksen sähkönsiirtoon sekä ...
Tammi, Veli Juhani
core   +1 more source

Overvoltage protection of large power transformers:a real life study case [PDF]

open access: yes, 2006
This paper demonstrates the results from a detailed study of the overvoltage protection of a particular 400/150 kV 400 MVA power transformer. The work presented here is based on real-life power system substation design and data and initiated by Danish ...
Bak, Claus Leth   +5 more
core   +2 more sources

Impact of Adding Fast Switching Fault Current Limiter (FSFCL) to the Neutral Point of 220 kV Transformer

open access: yesEnergies
In recent years, as the power grid continues to expand, the issue of asymmetrical short-circuit currents exceeding limits on the 220 kV medium-voltage side has become increasingly severe, and traditional current-limiting methods have certain limitations.
Lujian Dai   +8 more
doaj   +1 more source

Long-term field measurement and characteristics of lightning-induced overvoltages on 10 kV distribution lines in high-altitude mountainous areas and optimization of insulation coordination

open access: yesResults in Engineering
Aiming at the lack of measured data on lightning overvoltages in operational distribution networks and the irrationality of insulation coordination based on standard lightning impulse waveforms, this paper carries out large-scale and long-term ...
Li Shao   +6 more
doaj   +1 more source

A CASE STUDY OF OVERVOLTAGE PROTECTION OF A MICROWAVE REPEATER STATION

open access: yes, 2003
Ever since inception, the electric power and communication systems are exposed to dangerous overvoltage surges starting from lightning to service frequency temporary overvoltage waves with disastrous consequences.
Valsalal, P., Udayakumar, K.
core   +1 more source

Power plant lightning overvoltage protection of low voltage power electronics [PDF]

open access: yes, 2018
The effects of direct lightning strike and flashover strike to 400kV system of nuclear power plant were inspected for perspective of low voltage power electronic devices. Protection methods were simulated with PSCAD transient simulator.
Pasonen, Riku
core  