Results 71 to 80 of about 2,217,215 (210)
In recent years, with the rapid development of offshore wind turbines (WTs), the problem of lightning strikes has become more and more prominent. In order to reduce the failure rate caused by the transient overvoltage of lightning struck offshore WTs ...
Li Zhang +4 more
doaj +1 more source
A. Jalilian, K. Muttaqi, D. Sutanto
semanticscholar +1 more source
Aiming at the problem that train traction blocked caused by the line supply overvoltage of Ningbo rail transit line 2 phase 1 train, the cause was analyzed, and with the simulation, an improved solution of overvoltage protection logic according to the ...
YI Jian, HUANG Huijian
doaj
Lightning voltage impulse due to the waves of storm surge rolling out the high voltage line to a substation causes current to flow in the buses that, due to magnetic effect, induces overvoltage in the secondary circuit.
V. I. Glushko, E. A. Deryugina
doaj +1 more source
Response Characteristics of a ZnO Arrester Under Nanosecond Electromagnetic Pulse
Zinc oxide arresters, a major type of overvoltage protection equipment in power systems, can suppress transient lightning overvoltage, operation overvoltage, and other types of power surges.
Feng Qin +4 more
doaj +1 more source
IEEE Std 2800-2022 marks a major step forward in defining minimum technical requirements for connecting inverter-based resources (IBRs) to the Bulk Power System (BPS). However, as the standard gains wider adoption and real-world implementation progresses,
Mobolaji Bello +3 more
doaj +1 more source
Design of Fault Protection Stra for Unified Power Flow Controller in Distribution Networks
The capacity of traditional distribution networks is limited. After large-scale distributed power sources are connected, it is difficult to consume them at the same voltage level, which can lead to transformer reverse overloading and voltage limit ...
Xiaochun Mou +6 more
doaj +1 more source
Review of internal over-voltages in distribution networks 6…10 kV and means of their limitation has been carried out. One of the most efficient remedy for reduction of over-voltage at arcing ground is resistive neutral grounding.
A. N. Bokhan, V. V. Krotenok
doaj
In recent years, as the power grid continues to expand, the issue of asymmetrical short-circuit currents exceeding limits on the 220 kV medium-voltage side has become increasingly severe, and traditional current-limiting methods have certain limitations.
Lujian Dai +8 more
doaj +1 more source
Aiming at the lack of measured data on lightning overvoltages in operational distribution networks and the irrationality of insulation coordination based on standard lightning impulse waveforms, this paper carries out large-scale and long-term ...
Li Shao +6 more
doaj +1 more source