Results 71 to 80 of about 615,323 (354)

Evaluation of oesophageal pulse oximetry in patients undergoing cardiothoracic surgery [PDF]

open access: yes, 2003
Pulse oximetry probes placed peripherally may fail to give accurate values of blood oxygen saturation when the peripheral circulation is poor. Because central blood flow may be preferentially preserved, we investigated the oesophagus as an alternative ...
Bland   +14 more
core   +1 more source

Optimized Strategy for Fabricating High‐Aspect‐Ratio Periodic Structures Over Large Areas Using ps‐Direct Laser Interference Patterning

open access: yesAdvanced Engineering Materials, EarlyView.
Picosecond direct laser interference patterning (DLIP) enables precise microstructure fabrication on stainless steel. Using a multiscan approach, high‐aspect‐ratio patterns are achieved. Fluence influences structure growth and homogeneity, with smaller periods yielding better uniformity.
Fabian Ränke   +5 more
wiley   +1 more source

Development and Validation of Non simultaneous Retinal Image Acquisition–Based Retinal Oximeter

open access: yesScientific Reports, 2017
The purpose of this study was to develop and validate a tool for the measurement of retinal oxygen saturation using a conventional fundus camera–based nonsimultaneous imaging technique.
Sumeer Singh   +2 more
doaj   +1 more source

Normal jugular bulb oxygen saturation [PDF]

open access: yesJournal of Neurology, Neurosurgery & Psychiatry, 2003
Normal values of the jugular bulb oxygen saturation were obtained in 1942 and in 1963. Correct catheter positioning was not confirmed radiologically.To replicate the measurements during angiographic catheterisation of the jugular bulb.Oxygen saturation in the jugular bulb (SjO(2)), inferior petrosal sinus (SipsO(2)), and internal jugular vein was ...
CHIEREGATO A   +4 more
openaire   +4 more sources

Ag Cluster‐Modified K0.5Na0.5NbO3 Piezocatalyst for Enhanced Electrochemical Dinitrogen Reduction Reaction

open access: yesAdvanced Engineering Materials, EarlyView.
Ag cluster‐modified K0.5Na0.5NbO3 acts as an efficient piezocatalyst for electrochemical N2 reduction, enhanced by built‐in electric fields under mechanical actuation. Comparative studies between static and actuated electrodes reveal improved performance under dynamic conditions.
Benedict Witulski   +7 more
wiley   +1 more source

Influence of acute haemodynamic changes on the oxygen saturation during electro-convulsive therapy

open access: yesJournal of Neuroanaesthesiology and Critical Care, 2014
Background: Electro-convulsive therapy (ECT) is a safe and effective treatment for various psychiatric disorders. Among the various complications associated with ECT, acute haemodynamic responses and decrease in the oxygen saturation are the most common.
Sonia Bansal   +5 more
doaj   +1 more source

Oxygen saturation improvement after adenotonsillectomy in children. [PDF]

open access: yes, 2009
The goal of this study was to establish whether adenotonsillectomy is effective on the severity of oxygen desaturation or improve oxygen saturation in children with sleep breathing disorders.
Akhlaghi, Mahmood.   +2 more
core  

Surface Modification of Sol–Gel Synthesized Ba0.85Ca0.15Zr0.1Ti0.9O3 using Stearic Acid Additives

open access: yesAdvanced Engineering Materials, EarlyView.
This study explores a novel approach to enhance the piezoelectric performance of lead‐free BCZT ceramics synthesized via the sol–gel method. By coating the BCZT powder with only a 0.69 nm stearic acid layer, the electromechanical response is significantly boosted up to 359 pC N−1, revealing promising implications for high‐performance sensor and ...
Michelle Weichelt   +6 more
wiley   +1 more source

Value of brain tissue oxygen saturation in neonatal respiratory distress syndrome: a clinical study

open access: yesEuropean Journal of Translational Myology
Neonatal respiratory distress syndrome (NRDS) is one of the major causes of pre-term mortality and morbidity among very-low-birth-weight infants (VLBWI) in low- and middle-income countries (LMIC).
Keping Cheng   +4 more
doaj   +1 more source

Assessment of Pulp Oxygen Saturation Levels by Pulse Oximetry for Pulpal Diseases –A Diagnostic Study [PDF]

open access: yesJournal of Clinical and Diagnostic Research, 2017
Introduction: Diagnosis of pulpal inflammation is a key to endodontics. Pulse oximetry is a true vitality testing device which relies on oxygen saturation levels of pulp and helps in diagnosis of different pulpal conditions. Aim: The aim of the study
Bander Anusha   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy