Results 71 to 80 of about 11,177 (296)

Sterility and oxygenator function in pre-primed extracorporeal membrane oxygenation: A prospective clinical study

open access: yesResuscitation Plus
Aim: Minimizing cardiac arrest times is critical in extracorporeal cardiopulmonary resuscitation (ECPR). Pre-primed extra corporeal membrane oxygenator (ECMO) is used for this, but knowledge is limited to experimental studies.
Daniel Bengtsson   +2 more
doaj   +1 more source

Comparison of anticoagulation strategies for veno-venous ECMO support in acute respiratory failure

open access: yesCritical Care, 2021
Background Extracorporeal membrane oxygenation (ECMO) support in acute respiratory failure may be lifesaving, but bleeding and thromboembolic complications are common. The optimal anticoagulation strategy balancing these factors remains to be determined.
Benjamin Seeliger   +14 more
doaj   +1 more source

Intrinsic Photoactive Star ZnPc–Poly(glutamate) Nanoplatforms for Multimodal Glioblastoma Therapy and Brain‐Targeted Delivery

open access: yesAdvanced Functional Materials, EarlyView.
An intrinsic photoactive star‐shaped zinc phtalocyanine‐poly(L‐glutamic acid) (ZnPc‐PGA) nanoplatform for multimodal glioblastoma (GBM) therapy and brain‐targeted elivery. A ZnPc‐PGA‐based multifunctional theranostic nanocarrier platform enables image‐guided, multimodal GBM therapy. ZnPc‐PGA nanocarriers support the integration of fluorescence imaging,
Amina Benaicha‐Fernández   +14 more
wiley   +1 more source

Experimental and Clinical Studies for the Hollow Fiber Membrane Oxygenator [PDF]

open access: yes, 1981
The Hollow fiber membrane oxygenator (TERMO)? was studied experimentally, and was then used for 11 open heart surgeries. In the experiment, hemolysis and the pressure gradient across the oxygenator were observed using a model circuit.
上田, 睦   +8 more
core   +2 more sources

Poly2-methoxyethylacrylate (PMEA) Coated Oxygenator: An ex Vivo Study [PDF]

open access: yes, 2002
PMEA is a hydrophilic polymer coating with a unique design that minimizes the adsorption and denaturation of proteins and blood cells. This study compares thrombus resistance, blood path resistance, thrombocyte profile, and blood trauma of the PMEA ...
M. Augstburger   +4 more
core   +3 more sources

Electrospun Wood‐Derived Biopolymers as Electrodes in Electrochemical Energy Storage Technologies

open access: yesAdvanced Functional Materials, EarlyView.
Electrospinning transforms wood‐derived cellulose and lignin into architecturally defined, binder‐free carbon electrodes with tuneable porosity and functionality. This review shows how fibre design enables decoupled charge and mass transport, enhancing performance across battery systems, while identifying key challenges in spinnability, scalability ...
Michael W. Thielke   +3 more
wiley   +1 more source

A new oxygenator change-out system and procedure [PDF]

open access: yes, 2006
Official reports relate that, in the US, one patient/month dies as a result of the emergency oxygenator change-out procedure, and the permanent injury of some patients is the result of current oxygenator change-out procedures or oxygenator failures, both
DEGRASSI, Alberto   +5 more
core  

Effects of albumin and synthetic polypeptide-coated oxygenators on IL-1, IL-2, IL-6, and IL-10 in open heart surgery

open access: yesAsian Journal of Surgery, 2014
Background: In this study, we have tried to demonstrate the effects of coating style used in oxygenators on various hematologic and clinical parameters. Materials and methods: Twenty-seven patients were included in the study, who had undergone operations
Erdal Simsek   +4 more
doaj   +1 more source

Constraining the rise of oxygen with oxygen isotopes [PDF]

open access: yesNature Communications, 2019
AbstractAfter permanent atmospheric oxygenation, anomalous sulfur isotope compositions were lost from sedimentary rocks, demonstrating that atmospheric chemistry ceded its control of Earth’s surficial sulfur cycle to weathering. However, mixed signals of anoxia and oxygenation in the sulfur isotope record between 2.5 to 2.3 billion years (Ga) ago ...
Killingsworth, Bryan A.   +5 more
openaire   +5 more sources

Single‐Step Recovery of Water from Stable Crude Oil‐Water Emulsion Using Surface Engineered Hybrid Inorganic‐Polymer Membranes

open access: yesAdvanced Functional Materials, EarlyView.
Atomic layer deposition is used to conformally surface engineer polymeric membranes to fabricate inorganic–organic hybrid membranes. These membranes have exceptionally strong attraction toward water even in high oil containing emulsions, which leads to an extremely strong hydration layer at the interface.
Bratin Sengupta   +8 more
wiley   +1 more source