Results 151 to 160 of about 35,127 (267)

Cryoballoon Versus Radiofrequency Ablation for Persistent Atrial Fibrillation: Meta‐Analysis of Randomized Trials

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Introduction Pulmonary vein isolation (PVI) alone achieves modest arrhythmia freedom in persistent atrial fibrillation (PeAF). Cryoballoon ablation (CBA) offers a single‐shot alternative to radiofrequency ablation (RFA) that streamlines procedural workflow.
Harroop Bola   +8 more
wiley   +1 more source

Association of the HIGS score with permanent pacemaker implantation and mortality after transcatheter aortic valve implantation. [PDF]

open access: yesAnn Med
Karaca Ö   +11 more
europepmc   +1 more source

Management of Congenital Complete Atrioventricular Block in Preterm Neonates With Novel Pacing Method

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Congenital complete atrioventricular block (CCAVB) is a rare autoimmune mediated disorder with a guarded prognosis, particularly when associated with extreme prematurity and severe bradycardia. Recent advances in neonatal care for extremely premature infants with delivery at level IV neonatal intensive care unit and novel pediatric pacing ...
Anusha Bai Kalithkar   +5 more
wiley   +1 more source

Incidence and risk factors for permanent pacemaker implantation following aortic root surgery. [PDF]

open access: yesOpen Heart
Mani K   +7 more
europepmc   +1 more source

Transvenous Lead Extraction Versus Abandonment of non‐Infected, Superfluous Leads—A Meta‐Analysis and Systematic Review

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background Managing non‐functional cardiac implantable electronic device (CIED) leads remains controversial. While extraction is standard for infection, it is unclear whether transvenous lead extraction (TLE) or lead abandonment (LA) provides superior outcomes for superfluous leads.
Karanjeet Chauhan   +8 more
wiley   +1 more source

Internal Jugular Vein as an Alternative Access for Pacemaker Implantation: A Mostly Left IJ Case Series

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background Leadless pacemakers traditionally rely on femoral venous access, which may be limited in patients with unfavorable IVC anatomy, prior interventions, or situations where preserving femoral access is preferred. Internal jugular (IJ) access offers an alternative route, but real‐world data on IJ implantation of single‐ and dual‐chamber ...
Maya Asami Takagi   +3 more
wiley   +1 more source

Pacemaker Implantation Rates With the Self-Expandable Navitor Valve. [PDF]

open access: yesJ Am Heart Assoc
Paukovitsch M   +7 more
europepmc   +1 more source

Late Extraction of Micra AV and Implantation of Right Atrial Leadless Pacemaker

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background Tine‐based leadless pacemakers have been commercially implanted over the last 10 years. Retrieval of older devices is rarely discussed and based on rare case reports only. Methods A retrospective review of an extraction case of a Micra AV leadless pacemaker was performed. Internal Review Board approval was obtained.
Lydia Fekadu Messele   +3 more
wiley   +1 more source

AI-Enabled ECG Mapping to Guide Leadless Atrial Pacemaker Implantation in the Bachmann's Bundle Region. [PDF]

open access: yesJACC Case Rep
Qin D   +6 more
europepmc   +1 more source

Inpatient Cardiac Resynchronization Therapy During Heart Failure Hospitalization: A Distinct High‐Risk Phenotype

open access: yesPacing and Clinical Electrophysiology, EarlyView.
ABSTRACT Background The role of cardiac resynchronization therapy (CRT) during hospitalization for heart failure (HFH) is uncertain, because hospitalized patients were routinely excluded from landmark CRT trials. Despite this, CRT implantation during HFH is common.
Oliver Rees   +5 more
wiley   +1 more source

Home - About - Disclaimer - Privacy