Results 1 to 10 of about 19,907 (261)

Worsening Heart Failure due to AV Dissociation From Safety Mode in CRT‐P: A Case Requiring Urgent Generator Replacement [PDF]

open access: yesAnnals of Noninvasive Electrocardiology
Boston Scientific reported that dual chamber INGENIO family pacemakers or cardiac resynchronization therapy pacemakers (CRT‐P) may initiate safety mode. Once Safety Mode is activated, telemetry with the programmer becomes unavailable.
Yuki Osada   +4 more
doaj   +2 more sources

A Meta-analysis of Major Complications between Traditional Pacemakers and Leadless Pacemakers

open access: yesCardiovascular Innovations and Applications, 2021
Objectives: We aim to compare the major complications between leadless pacemakers and traditional pacemakers. Background: Leadless pacemakers, which are increasingly used in clinical practice, have several advantages compared with traditional ...
Diyu Cui   +3 more
doaj   +1 more source

Evolution of cardiac pacemakers: a journey from Galvanic experiments to leadless pacemakers

open access: yesHeart Vessels and Transplantation, 2023
The development of cardiac pacemakers has a rich history spanning over two centuries, beginning with Luigi Galvani's discovery of the heart's response to electrical currents in the late 18th century.
Abay Bakytzhanuly
doaj   +1 more source

Tricuspid Valve Replacement in a Patient with a Leadless Cardiac Pacemaker: Current Guidelines and Recommendations for Perioperative Management

open access: yesCase Reports in Anesthesiology, 2021
Leadless cardiac pacemakers were developed to reduce complications associated with conventional transvenous pacemakers. While this technology is still relatively new, devices are increasingly being implanted. The perioperative management of patients with
River Hames   +8 more
doaj   +1 more source

Comparison of Anxiety and Depression Symptoms in Individuals According to their Sex, Type of Cardiac Device, and Diagnosis of Chagas Disease

open access: yesBrazilian Journal of Cardiovascular Surgery, 2022
Introduction: Implantable cardiac pacemakers or cardioverter defibrillators are alternatives for the treatment of arrhythmias, however, their use has caused changes in the emotional state of patients.
Carina Aparecida Marosti Dessotte   +6 more
doaj   +1 more source

On the Evolution of the Cardiac Pacemaker [PDF]

open access: yesJournal of Cardiovascular Development and Disease, 2017
The rhythmic contraction of the heart is initiated and controlled by an intrinsic pacemaker system. Cardiac contractions commence at very early embryonic stages and coordination remains crucial for survival. The underlying molecular mechanisms of pacemaker cell development and function are still not fully understood.
Silja Burkhard   +4 more
openaire   +4 more sources

Data deluge from remote monitoring of cardiac implantable electronic devices and importance of clinical stratification

open access: yesHeart Rhythm O2, 2023
Background: Remote monitoring (RM) has been accepted as a standard of care for follow-up of patients with cardiac implantable electronic devices (CIEDs). However, the resulting data deluge poses major challenge to device clinics.
Danish Bawa, MD   +7 more
doaj   +1 more source

Sacral Neuromodulation in Patients With a Cardiac Pacemaker [PDF]

open access: yesInternational Neurourology Journal, 2016
The objective of this study was to describe our experience using sacral neuromodulation to treat urinary urgency, frequency, urge incontinence, and chronic urinary retention in patients with cardiac pacemakers.
Abdullah A. Gahzi   +2 more
doaj   +1 more source

Symbiotic cardiac pacemaker [PDF]

open access: yesNature Communications, 2019
AbstractSelf-powered implantable medical electronic devices that harvest biomechanical energy from cardiac motion, respiratory movement and blood flow are part of a paradigm shift that is on the horizon. Here, we demonstrate a fully implanted symbiotic pacemaker based on an implantable triboelectric nanogenerator, which achieves energy harvesting and ...
Han Ouyang   +14 more
openaire   +3 more sources

Comparison of cardiac function before and after Micra implantation using pool scintigraphy and myocardial work: A case report

open access: yesRadiology Case Reports, 2023
Leadless pacemakers, specifically Micra (Medtronic), have recently become a preferred alternative to transvenous pacemakers for use in bradyarrhythmia.
Naoya Inoue, MD   +2 more
doaj   +1 more source

Home - About - Disclaimer - Privacy